"manufacturer": "ShenZhen Sunricher Technology, Ltd.",
"manufacturerId": "0x0330",
"label": "SR-ZV9092A",
"description": "Thermostat",
"devices": [
{
"productType": "0x0200",
"productId": "0xd013",
"zwaveAllianceId": 4289
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
},
"2": {
"label": "Heat Set",
"maxNodes": 5
}
},
"paramInformation": [
{
"#": "2",
"label": "Overcurrent Protection",
"description": "Allowable range: 5-16",
"valueSize": 1,
"unit": "A",
"minValue": 0,
"maxValue": 16,
"defaultValue": 16,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "3",
"label": "Button Vibrations & Sounds",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "Low",
"value": 1
},
{
"label": "High",
"value": 2
}
]
},
{
"#": "4",
"label": "Settings After Power Failure",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Default settings",
"value": 0
},
{
"label": "Recover to prior settings",
"value": 1
}
]
},
{
"#": "6",
"label": "Overheat Protection",
"description": "Allowable range: 20-60",
"valueSize": 1,
"unit": "°C",
"minValue": 0,
"maxValue": 60,
"defaultValue": 45,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "7",
"label": "Temperature Control Hysteresis",
"valueSize": 1,
"unit": "0.1 °C",
"minValue": 5,
"maxValue": 20,
"defaultValue": 5
},
{
"#": "8",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Energy Saver Mode"
},
{
"#": "9",
"label": "Temperature Sensor Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Ntc/10k b(25/50℃)=3950",
"value": 1
},
{
"label": "Ntc/15k b(25/50℃)=3950",
"value": 2
},
{
"label": "Ntc/50k b(25/50℃)=3950",
"value": 3
},
{
"label": "Ntc/100k b(25/50℃)=3950",
"value": 4
}
]
},
{
"#": "10",
"label": "Temperature Control Reference",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Room sensor",
"value": 1
},
{
"label": "Floor sensor",
"value": 2
},
{
"label": "Room and floor sensor",
"value": 3
}
]
},
{
"#": "11",
"label": "Room Sensor Offset",
"valueSize": 1,
"unit": "0.5 °C",
"minValue": -10,
"maxValue": 10,
"defaultValue": 0
},
{
"#": "12",
"label": "Floor Sensor Offset",
"valueSize": 1,
"unit": "0.5 °C",
"minValue": -10,
"maxValue": 10,
"defaultValue": 0
},
{
"#": "13",
"label": "Drying Mode Duration",
"valueSize": 1,
"unit": "minutes",
"minValue": 5,
"maxValue": 100,
"defaultValue": 5
},
{
"#": "14",
"label": "Mode to Set After Drying Mode",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Off",
"value": 0
},
{
"label": "Manual/Comfort",
"value": 1
},
{
"label": "Auto/Energy saver",
"value": 2
},
{
"label": "Away",
"value": 3
}
]
},
{
"#": "16",
"label": "Automatic Reporting: Temperature Change Threshold",
"description": "Allowable range: 2-10",
"valueSize": 1,
"unit": "0.1 °C",
"minValue": 0,
"maxValue": 10,
"defaultValue": 2,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "17",
"label": "Automatic Reporting: Humidity Reporting Interval",
"description": "Allowable range: 30-28800",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 28800,
"defaultValue": 300,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "18",
"label": "Automatic Reporting: Power Change Threshold",
"valueSize": 1,
"unit": "W",
"minValue": 0,
"maxValue": 100,
"defaultValue": 5,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "19",
"label": "Automatic Reporting: Current Change Threshold",
"valueSize": 1,
"unit": "0.1 A",
"minValue": 0,
"maxValue": 10,
"defaultValue": 10,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "20",
"label": "Automatic Reporting: Voltage Change Threshold",
"valueSize": 1,
"unit": "V",
"minValue": 0,
"maxValue": 10,
"defaultValue": 2,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "21",
"label": "Automatic Reporting: Meter Report Interval",
"valueSize": 4,
"unit": "seconds",
"minValue": 60,
"maxValue": 2678400,
"defaultValue": 600
},
{
"#": "22",
"label": "Display Brightness",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Low",
"value": 0
},
{
"label": "Medium",
"value": 1
},
{
"label": "High",
"value": 2
}
]
},
{
"#": "23",
"label": "Home Page Sensor Display",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Indoor air temperature",
"value": 0
},
{
"label": "External temperature (Floor temperature)",
"value": 1
}
]
},
{
"#": "24",
"label": "Time Zone Differential",
"description": "Specify the time difference from UTC",
"valueSize": 1,
"minValue": -12,
"maxValue": 12,
"defaultValue": 0
},
{
"#": "26",
"label": "Window Open Detection",
"description": "Specifies the temperature change within three minutes to trigger window open detection",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "1.5 °C",
"value": 15
},
{
"label": "2.0 °C",
"value": 20
},
{
"label": "2.5 °C",
"value": 25
},
{
"label": "3.0 °C",
"value": 30
},
{
"label": "3.5 °C",
"value": 35
},
{
"label": "4.0 °C",
"value": 40
}
]
}
],
"metadata": {
"inclusion": "Adding to a Z-Wave Network (Inclusion)\nMethod 1: Select “Add”, then short press button , the device will send out inclusion request, “Status” will show “Inclusion...”. If there is no response from a gateway within 30 seconds, or inclusion failed, “Status” will show “Fail”. If included successfully, “Status” will show “Inclusion OK” and device ID.\nMethod 2: Operate the gateway into inclusion mode, make sure the device is already removed from previous network, reset power of the device, the device will be included to the gateway automatically",
"exclusion": "Removing from a Z-Wave Network (Exclusion)\nSelect “Remove”, then short press button , the device will send out exclusion request, “Status” will show “Exclusion...”. If there is no response from a gateway within 30 seconds, or exclusion failed, “Status” will show “Fail”. If excluded successfully, “Status” will show “Exclusion OK” and device ID will be showed as 0",
"reset": "Select “Reset”, then short press button F, the device will start reset, “Status” will show “Reset...”. If there is no response from a gateway within 6 seconds, or exclusion failed, “Status” will show “Fail”. If reset successfully, “Status” will show “Reset OK”",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4289/SR-ZV9092A%20instructionRelease.pdf"
}
}