"manufacturer": "EVA Logik",
|
|
"manufacturerId": "0x0312",
|
|
"label": "ZW31",
|
|
"description": "S2 In-Wall Smart Dimmer Switch",
|
|
"devices": [
|
|
{
|
|
"productType": "0xa000",
|
|
"productId": "0xaa02",
|
|
"zwaveAllianceId": 3602
|
|
},
|
|
{
|
|
"productType": "0xb112",
|
|
"productId": "0x1f1c",
|
|
"zwaveAllianceId": 2354
|
|
},
|
|
{
|
|
"productType": "0xff00",
|
|
"productId": "0xff04",
|
|
"zwaveAllianceId": 3403
|
|
},
|
|
{
|
|
"productType": "0xff01",
|
|
"productId": "0xff04",
|
|
"zwaveAllianceId": 3610
|
|
},
|
|
{
|
|
"productType": "0xee00",
|
|
"productId": "0xee02",
|
|
"zwaveAllianceId": 3993
|
|
},
|
|
{
|
|
"productType": "0xaa00",
|
|
"productId": "0xaa02"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Button Orientation",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Normal orientation",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Swap up/down buttons",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Both buttons toggle",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"$import": "~/templates/master_template.json#led_indicator_four_options"
|
|
},
|
|
{
|
|
"#": "3",
|
|
"$import": "~/templates/master_template.json#base_enable_disable",
|
|
"label": "Enable/Disable Auto-Off Timer"
|
|
},
|
|
{
|
|
"#": "4",
|
|
"$import": "~/templates/master_template.json#base_1-65535",
|
|
"label": "Auto-Off Timer",
|
|
"unit": "minutes",
|
|
"defaultValue": 60
|
|
},
|
|
{
|
|
"#": "5",
|
|
"$import": "~/templates/master_template.json#base_enable_disable",
|
|
"label": "Enable/Disable Auto-On Timer"
|
|
},
|
|
{
|
|
"#": "6",
|
|
"$import": "~/templates/master_template.json#base_1-65535",
|
|
"label": "Auto-On Timer",
|
|
"unit": "minutes",
|
|
"defaultValue": 60
|
|
},
|
|
{
|
|
"#": "7[0x01]",
|
|
"$import": "templates/minoston_template.json#status_change_report_local_control"
|
|
},
|
|
{
|
|
"#": "7[0x02]",
|
|
"$import": "templates/minoston_template.json#status_change_report_three_way"
|
|
},
|
|
{
|
|
"#": "7[0x04]",
|
|
"$import": "templates/minoston_template.json#status_change_report_zwave"
|
|
},
|
|
{
|
|
"#": "7[0x08]",
|
|
"$import": "templates/minoston_template.json#status_change_report_timer"
|
|
},
|
|
{
|
|
"#": "8",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev"
|
|
},
|
|
{
|
|
"#": "9",
|
|
"label": "Dimmer Speed (Manual)",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 99,
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"#": "10",
|
|
"label": "Minimum Dim Level",
|
|
"valueSize": 1,
|
|
"minValue": 1,
|
|
"maxValue": 99,
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"#": "11",
|
|
"label": "Maximum Dim Level",
|
|
"valueSize": 1,
|
|
"minValue": 1,
|
|
"maxValue": 99,
|
|
"defaultValue": 99
|
|
},
|
|
{
|
|
"#": "12",
|
|
"label": "Dim Level on Double Tap",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Full brightness",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Maximum dim level",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "14",
|
|
"label": "Double Tap Behavior",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Maximum dim level",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Disable double tap; Single tap to last level",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Disable double tap, single tap to full brightness",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "15",
|
|
"$import": "templates/minoston_template.json#enable_local_control"
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network.\n2. Once the controller is ready to include your device, press up and release the toggle three times to include it in the network.\n3. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance.\n4. The device is associated in the same group when it included in setting process.",
|
|
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.\n2. Once the controller is ready to Exclude your device, press up and release the front button Three times to exclude it from the network.",
|
|
"reset": "Press click Z-Wave button3 times quickly,and hold the third time for at least 10 seconds. to restore the device to the factory.Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3602/ZW31manual_EVALOGIK-190718-1.pdf"
|
|
}
|
|
}
|