"manufacturer": "Z-works Inc.",
"manufacturerId": "0x024d",
"label": "DN3G6JA062",
"description": "Lock Detector",
"devices": [
{
"productType": "0x4761",
"productId": "0x0001",
"zwaveAllianceId": 1651
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Polling Interval",
"valueSize": 1,
"unit": "seconds",
"minValue": 30,
"maxValue": 127,
"defaultValue": 60
},
{
"#": "2",
"label": "LED Blinking Mode",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "LED indicator is always off",
"value": 0
},
{
"label": "LED indicator lights 1 second after opening",
"value": 1
},
{
"label": "LED indicator lights 1 second after closing",
"value": 2
},
{
"label": "LED indicator lights 1 second after opening and closing",
"value": 3
}
]
}
],
"metadata": {
"inclusion": "Using a paper clip or equivalent, push the button over 3 seconds.\n(Please note that this product is reset if switch is pushed over 10 seconds)\nStatus LED turns off after adding",
"exclusion": "Using a paper clip or equivalent, push the button over 3 seconds.\n(Please note that this product is reset if switch is pushed over 10 seconds)\nStatus LED starts flashing after removal is finished",
"reset": "Using a paper clip or equivalent, push the button over 10 seconds.\nUse this procedure only in the event that the network primary controller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1651/User's%20Guide%20151215_160310_updated.pdf"
}
}