279 lines
4.8 KiB
JSON
279 lines
4.8 KiB
JSON
{
|
|
"manufacturer": "Heatit",
|
|
"manufacturerId": "0x019b",
|
|
"label": "Z-TRM2fx",
|
|
"description": "Floor Thermostat",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0003",
|
|
"productId": "0x0202"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "3.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Operation Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Off",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Heating mode",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Cooling mode (Not implemented)",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Energy saving heating mode",
|
|
"value": 11
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Sensor Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "F-Mode, floor sensor mode",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "A2-mode, external room sensor mode",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "A2F-mode, external sensor with floor limitation",
|
|
"value": 4
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Floor Sensor Type",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "10K-NTC",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "12K-NTC",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "15K-NTC",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "22K-NTC",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "33K-NTC",
|
|
"value": 4
|
|
},
|
|
{
|
|
"label": "47K-NTC",
|
|
"value": 5
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Temperature Control Hysteresis (DIFF I)",
|
|
"valueSize": 1,
|
|
"minValue": 3,
|
|
"maxValue": 30,
|
|
"defaultValue": 5
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "Floor Minimum Temperature Limit (FLo)",
|
|
"valueSize": 2,
|
|
"unit": "oC",
|
|
"minValue": 50,
|
|
"maxValue": 400,
|
|
"defaultValue": 50
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Floor Maximum Temperature (FHi)",
|
|
"valueSize": 2,
|
|
"unit": "oC",
|
|
"minValue": 50,
|
|
"maxValue": 400,
|
|
"defaultValue": 400
|
|
},
|
|
{
|
|
"#": "7",
|
|
"label": "Air (A2) Minimum Temperature Limit (ALo)",
|
|
"valueSize": 2,
|
|
"unit": "oC",
|
|
"minValue": 50,
|
|
"maxValue": 400,
|
|
"defaultValue": 50
|
|
},
|
|
{
|
|
"#": "8",
|
|
"label": "Air (A2) Maximum Temperature Limit (AHi)",
|
|
"valueSize": 2,
|
|
"unit": "oC",
|
|
"minValue": 50,
|
|
"maxValue": 400,
|
|
"defaultValue": 400
|
|
},
|
|
{
|
|
"#": "9",
|
|
"label": "Heating Mode Setpoint (CO)",
|
|
"valueSize": 2,
|
|
"unit": "oC",
|
|
"minValue": 50,
|
|
"maxValue": 400,
|
|
"defaultValue": 210
|
|
},
|
|
{
|
|
"#": "10",
|
|
"label": "Energy Saving Mode Setpoint (ECO)",
|
|
"valueSize": 2,
|
|
"unit": "oC",
|
|
"minValue": 50,
|
|
"maxValue": 400,
|
|
"defaultValue": 180
|
|
},
|
|
{
|
|
"#": "11",
|
|
"label": "Cooling Setpoint (COOL)",
|
|
"valueSize": 2,
|
|
"unit": "oC",
|
|
"minValue": 50,
|
|
"maxValue": 400,
|
|
"defaultValue": 210
|
|
},
|
|
{
|
|
"#": "12",
|
|
"label": "Floor Sensor Calibration",
|
|
"valueSize": 1,
|
|
"unit": "oC",
|
|
"minValue": -40,
|
|
"maxValue": 40,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "13",
|
|
"label": "External Sensor Calibration",
|
|
"valueSize": 1,
|
|
"unit": "oC",
|
|
"minValue": -40,
|
|
"maxValue": 40,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "14",
|
|
"label": "Temperature Display",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Display setpoint temperature",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Display measured temperature",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "15",
|
|
"label": "Button Brightness - Dimmed State",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 50
|
|
},
|
|
{
|
|
"#": "16",
|
|
"label": "Button Brightness - Active State",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 100
|
|
},
|
|
{
|
|
"#": "17",
|
|
"label": "Display Brightness - Dimmed State",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 50
|
|
},
|
|
{
|
|
"#": "18",
|
|
"label": "Display Brightness - Active State",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 100
|
|
},
|
|
{
|
|
"#": "19",
|
|
"label": "Temperature Report Interval",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 60
|
|
},
|
|
{
|
|
"#": "20",
|
|
"label": "Temperature Report Hysteresis",
|
|
"valueSize": 1,
|
|
"unit": "oC",
|
|
"minValue": 1,
|
|
"maxValue": 100,
|
|
"defaultValue": 10
|
|
},
|
|
{
|
|
"#": "21",
|
|
"label": "Meter Report Interval",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 60
|
|
},
|
|
{
|
|
"#": "22",
|
|
"label": "Meter Report Delta Value",
|
|
"valueSize": 1,
|
|
"unit": "kWh/10",
|
|
"minValue": 0,
|
|
"maxValue": 127,
|
|
"defaultValue": 10
|
|
}
|
|
],
|
|
"compat": {
|
|
// Stop this device from flooding the network with hundreds of invalid reports
|
|
"skipConfigurationInfoQuery": true
|
|
}
|
|
}
|