"manufacturer": "Climax Technology, Ltd.",
|
|
"manufacturerId": "0x018e",
|
|
"label": "DC-23ZW",
|
|
"description": "Door Contact",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0001",
|
|
"productId": "0x0007",
|
|
"zwaveAllianceId": 2542
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"metadata": {
|
|
"inclusion": "1. Pull out the battery insulator; this will connect the battery to power on the Door Contact.\n\n2. Put the Z-Wave Gateway or Control Panel into Inclusion mode (Please refer to the Z-Wave Gateway or Control Panel manual).\n\n3. Press the Function button 3 times within 1.5 seconds.\n\n4. Refer to the operation manual of the Z-Wave Gateway or Control Panel to complete adding process.\n\n5. If the Door Contact has already been added (included) into another Z-Wave Gateway/Control Panel, or if the Door Contact is unable to be added into the current Z-Wave Gateway/Control Panel, please exclude it first (see Removing Device) before attempting to include it into the current Z-Wave Gateway/Control Panel",
|
|
"exclusion": "1. Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).\n\n2. Within 1.5 seconds, press the Function Button 3 times and the Door Contact will be removed from the Z-Wave network",
|
|
"reset": "Press and hold the Function Button of the Door Contact for 10 seconds to factory reset (only use factory reset when network Control Panel/Gateway is missing or inoperable)",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2542/DC-23ZW%20Manual.pdf"
|
|
}
|
|
}
|