zwave-js/.config-db/devices/0x018e/bx-32zw.json
2025-01-10 22:05:04 -08:00

23 lines
2.5 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

{
"manufacturer": "Climax Technology, Ltd.",
"manufacturerId": "0x018e",
"label": "BX-32ZW",
"description": "Outdoor Siren",
"devices": [
{
"productType": "0x0002",
"productId": "0x000b",
"zwaveAllianceId": 2156
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"metadata": {
"inclusion": "This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.\n - Insert the two 1.5V D-Cell alkaline batteries into the battery \n compartment connecting the correct polarity as shown on the\n battery compartment lid.\n - The Bellbox will emit a 2-tone beep.\n Put the Z-Wave gateway or control panel into Inclusion mode (please \n refer to the Z-Wave gateway or control panel manual).\n - Within 1.5 seconds, press the Function Button 3 times.\n - Refer to the operation manual of the Z-Wave Gateway or Control \n Panel to complete the adding process.\n - If the sensor has already been added (included) into another Z-Wave \n Gateway/Control Panel, or if the sensor is unable to be added into \n the current Z-Wave Gateway/Control Panel, please exclude it first \n (see Removing Device) before attempting to include it into the \n current Z-Wave Gateway/Control Panel.",
"exclusion": "The Bellbox must be removed from existing Z-Wave network before being included into another. There are two methods available to exclude a device.\nExclusion Mode\n - Put the Z-Wave gateway or control panel into Exclusion mode \n (please refer to the Z-Wave gateway or control panel manual).\n - Within 1.5 seconds, press the Function Button 3 times and the \n Bellbox will be removed from the Z-Wave network.",
"reset": "Factory Reset\n(Only use factory reset when network Control Panel/Gateway is missing or inoperable).\n - Press and hold the Function button of the Bellbox for 10 seconds to \n factory reset with all LED flashes once.\n <NOTE>\n Factory resetting the Bellbox will restore it to factory default \n settings (excluded from the Z-Wave network). The Z-Wave gateway \n or control panel will still keep its Z-Wave settings. Please refer to \n the gateway or control panel manual on how to remove the \n Bellboxs Z-Wave settings.",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2156/BX-32ZW_20161229.docx"
}
}