"manufacturer": "Devolo",
|
|
"manufacturerId": "0x0175",
|
|
"label": "MT2652",
|
|
"description": "Scene Switch",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0100",
|
|
"productId": "0x0101",
|
|
"zwaveAllianceId": 1143
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Button 1 and 3 Pair Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Separately",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "In pair without double clicks",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "In pair with double clicks",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Button 2 and 4 Pair Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Separately",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "In pair without double clicks",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "In pair with double clicks",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "11",
|
|
"label": "Command to Control Group A",
|
|
"valueSize": 1,
|
|
"defaultValue": 8,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disabled",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Switch on/off/dim (Basic Set / Multilevel Switch)",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Switch on/off only (Send Basic Set)",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Switch all",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "Send scenes",
|
|
"value": 4
|
|
},
|
|
{
|
|
"label": "Send preconfigured scenes",
|
|
"value": 5
|
|
},
|
|
{
|
|
"label": "Control devices in proximity",
|
|
"value": 6
|
|
},
|
|
{
|
|
"label": "Control door lock",
|
|
"value": 7
|
|
},
|
|
{
|
|
"label": "Central Scene to gateway",
|
|
"value": 8
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "12",
|
|
"label": "Command to Control Group B",
|
|
"valueSize": 1,
|
|
"defaultValue": 8,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disabled",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Switch on/off/dim (Basic Set / Multilevel Switch)",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Switch on/off only (Send Basic Set)",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Switch all",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "Send scenes",
|
|
"value": 4
|
|
},
|
|
{
|
|
"label": "Send preconfigured scenes",
|
|
"value": 5
|
|
},
|
|
{
|
|
"label": "Control devices in proximity",
|
|
"value": 6
|
|
},
|
|
{
|
|
"label": "Control door lock",
|
|
"value": 7
|
|
},
|
|
{
|
|
"label": "Central Scene to gateway",
|
|
"value": 8
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "13",
|
|
"label": "Command to Control Group C",
|
|
"valueSize": 1,
|
|
"defaultValue": 8,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disabled",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Switch on/off/dim (Basic Set / Multilevel Switch)",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Switch on/off only (Send Basic Set)",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Switch all",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "Send scenes",
|
|
"value": 4
|
|
},
|
|
{
|
|
"label": "Send preconfigured scenes",
|
|
"value": 5
|
|
},
|
|
{
|
|
"label": "Control devices in proximity",
|
|
"value": 6
|
|
},
|
|
{
|
|
"label": "Control door lock",
|
|
"value": 7
|
|
},
|
|
{
|
|
"label": "Central Scene to gateway",
|
|
"value": 8
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "14",
|
|
"label": "Command to Control Group D",
|
|
"valueSize": 1,
|
|
"defaultValue": 8,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disabled",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Switch on/off/dim (Basic Set / Multilevel Switch)",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Switch on/off only (Send Basic Set)",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Switch all",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "Send scenes",
|
|
"value": 4
|
|
},
|
|
{
|
|
"label": "Send preconfigured scenes",
|
|
"value": 5
|
|
},
|
|
{
|
|
"label": "Control devices in proximity",
|
|
"value": 6
|
|
},
|
|
{
|
|
"label": "Control door lock",
|
|
"value": 7
|
|
},
|
|
{
|
|
"label": "Central Scene to gateway",
|
|
"value": 8
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "21",
|
|
"label": "Send the Following Switch All Commands",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"unsigned": true,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Switch off only",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Switch on only",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Switch all on and off",
|
|
"value": 255
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "22",
|
|
"label": "Invert Buttons",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "No",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Yes",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "25",
|
|
"label": "Block Wake Up Even When Wake Up Interval Is Set",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Wake up is blocked",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Wakeup is not blocked",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "30",
|
|
"label": "Send Unsolicited Battery Report on Wake Up",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "No",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "To same node as wake up notification",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Broadcast to neighbours",
|
|
"value": 2
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "Place your primary controller in inclusion mode by following the manufacturer's instructions, then activate inclusion on the wall controller by pressing any one of the four buttons for one second. Inclusion mode is indicated by the red/green blinking of the LEDs until the timeout occurs after 10 seconds",
|
|
"exclusion": "Re-Inclusion and Exclusion are performed by pushing button 1 in management mode. Pushing all four buttons for 5 sec. turns the device into management mode (indicated by blinking green LED)",
|
|
"reset": "Use this procedure only if the primary controller is missing or otherwise inoperable. \n(1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 3, (3) keep button 4 pushed for 4 seconds",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1143/SceneSwitch_Manual.docx"
|
|
}
|
|
}
|