"manufacturer": "Leak Intelligence, LLC",
|
|
"manufacturerId": "0x0173",
|
|
"label": "LGRM",
|
|
"description": "Leak Gopher Meter Reader",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0003",
|
|
"productId": "0x0003",
|
|
"zwaveAllianceId": 1842
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Debounce",
|
|
"description": "If meter pulses are more than 100/second, lower debounce. If incrementing by more than 1 with each pulse, debounce should be increased",
|
|
"valueSize": 1,
|
|
"minValue": 1,
|
|
"maxValue": 255,
|
|
"defaultValue": 10,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Report Rate Interval (Controller)",
|
|
"valueSize": 1,
|
|
"unit": "minutes",
|
|
"minValue": 0,
|
|
"maxValue": 255,
|
|
"defaultValue": 10,
|
|
"unsigned": true,
|
|
"options": [
|
|
{
|
|
"label": "Disabled",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Report Rate Interval (Association Group 1)",
|
|
"valueSize": 1,
|
|
"unit": "x 6 minutes",
|
|
"minValue": 0,
|
|
"maxValue": 255,
|
|
"defaultValue": 0,
|
|
"unsigned": true,
|
|
"options": [
|
|
{
|
|
"label": "Disabled",
|
|
"value": 0
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "How to Add the Leak Gopher Meter Reader to your Z-Wave Controller \n- Plug the wall cube power adapter (included) into the receptacle on the bottom of the Leak Gopher marked “12 VDC”. Plug the wall cube into a 110 VAC outlet. \nThis provides power to the Leak Gopher. \n- Configure the Z-Wave Controller to Include/Add a device. \n- When the Z-Wave Controller is ready to include/add a device, it will display a message like “waiting to add device”. Press Include/Add button on the front of the device. \n- The Include/Exclude button is the Z-Wave logo located on the front of the Leak Gopher Meter Reader.\n- Press the Include/Remove button. Depending on your controller you may have to press the button 3 times. \n- The Z-Wave Controller will acknowledge that the Leak Gopher Meter Reader has been added to the Z-Wave network. \n- Your Leak Gopher Meter Reader is ready to use.",
|
|
"exclusion": "How to Remove the Leak Gopher Meter Reader from your Z-Wave Controller \n- Plug the wall cube power adapter (included) into the receptacle on the bottom of the Leak Gopher Meter Reader marked “12 VDC”. Plug the wall cube into a 110 VAC outlet. \nThis provides power to the Leak Gopher Meter Reader. \n- Configure the Z-Wave Controller to Exclude a device. \n- When the Z-Wave Controller is ready to exclude a device, it will display a message like \n“waiting to exclude device. Press exclude button on the device” \n- The Include/Exclude button is the Z-Wave logo located on the front of the Leak Gopher Meter Reader.\n- Press the Include/Remove button. Depending on your controller you may have to press the button 3 times. \n- The Z-Wave Controller will acknowledge that the Leak Gopher Meter Reader has been excluded from the Z-Wave network. \n- Your Leak Gopher Meter Reader is excluded from this controller.",
|
|
"reset": "How to reset the Leak Gopher Meter Reader\n- If the exclusion process above is not working or the Z-Wave controller that was originally joined to is lost or not available, the following process can be used to factory reset the device to the same state it has when shipped new. \n- To reset the Leak Gopher Meter Reader Z-Wave radio and routing tables, press and hold the Include/Exclude button located on the front of the Leak Gopher Meter Reader for 15 seconds.",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1842/LeakGopherMeterReaderZ-WaveUserManual.pdf"
|
|
}
|
|
}
|