"manufacturer": "McoHome Technology Co., Ltd.",
|
|
"manufacturerId": "0x015f",
|
|
"label": "MH-S212",
|
|
"description": "Mini Combo Switch Two-Load",
|
|
"devices": [
|
|
{
|
|
"productType": "0x2121",
|
|
"productId": "0x1352"
|
|
},
|
|
{
|
|
"productType": "0x2121",
|
|
"productId": "0x1353"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"associations": {
|
|
"1": {
|
|
"label": "Report",
|
|
"maxNodes": 5,
|
|
"isLifeline": true
|
|
}
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev"
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "External Switch Type",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Momentary buttons",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "2-State switches",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "2-State Switches",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Toggle switch without specified on/off position",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Toggle switch with specified on/off position",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Switch 1 - Operation Report to Association Group 1",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Report both on/off",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Report on only",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Report off only",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "Switch 1 - Off Timer",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Switch 1 - Off Timer Interval",
|
|
"valueSize": 2,
|
|
"unit": "100ms",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "7",
|
|
"label": "Switch 1 - Operation Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Switch immediately",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Zero crossing switch",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "8",
|
|
"label": "Switch 2 - Operation Report to Association Group 2",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Report both on/off",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Report on only",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Report off only",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "255",
|
|
"label": "Factory Reset",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"writeOnly": true,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "No",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Factory reset",
|
|
"value": 85
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|