zwave-js/.config-db/devices/0x0159/zmnhnd.json
2025-01-10 22:05:04 -08:00

205 lines
3.6 KiB
JSON

{
"manufacturer": "Qubino",
"manufacturerId": "0x0159",
"label": "ZMNHND",
"description": "Flush 1D Relay",
"devices": [
{
"productType": "0x0002",
"productId": "0x0053"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Input 1 Switch Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Mono-Stable switch type (Push button)",
"value": 0
},
{
"label": "Bi-Stable switch type",
"value": 1
}
]
},
{
"#": "2",
"label": "Input 2 Contact Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "NO (Normally open) input type",
"value": 0
},
{
"label": "NC (Normally close) input type",
"value": 1
}
]
},
{
"#": "10",
"label": "Activate / Deactivate Functions ALL ON/ALL OFF",
"valueSize": 1,
"defaultValue": 255,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "All on is not active all off is not active",
"value": 0
},
{
"label": "All on is not active all off active",
"value": 1
},
{
"label": "All on active all off is not active",
"value": 2
},
{
"label": "All on active, all off active",
"value": 255
}
]
},
{
"#": "11",
"label": "Automatic Turning Off Relay After Set Time",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0,
"unsigned": true,
"options": [
{
"label": "Auto off disabled",
"value": 0
}
]
},
{
"#": "12",
"label": "Automatic Turning on Relay After Set Time",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0,
"unsigned": true,
"options": [
{
"label": "Auto on disabled",
"value": 0
}
]
},
{
"#": "15",
"label": "Auto Turn Off / on Seconds or Milliseconds",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Seconds selected",
"value": 0
},
{
"label": "Milliseconds selected",
"value": 1
}
]
},
{
"#": "30",
"$import": "~/templates/master_template.json#state_after_power_failure_prev_off"
},
{
"#": "63",
"label": "Output Switch Selection",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Output 0V when system turned off",
"value": 0
},
{
"label": "Output 230V or 24V when system turned off",
"value": 1
}
]
},
{
"#": "100",
"label": "Endpoint I2 Notification and Event",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Endpoint, I2 disabled",
"value": 0
},
{
"label": "Home security",
"value": 1
},
{
"label": "Carbon monoxide",
"value": 2
},
{
"label": "Carbon dioxide",
"value": 3
},
{
"label": "Water alarm",
"value": 4
},
{
"label": "Heat alarm",
"value": 5
},
{
"label": "Smoke alarm",
"value": 6
},
{
"label": "Binary Sensor",
"value": 9
}
]
},
{
"#": "110",
"label": "Temperature Sensor Offset Settings",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 32536,
"unsigned": true
},
{
"#": "120",
"label": "Digital Temperature Sensor Reporting",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 5,