zwave-js/.config-db/devices/0x0159/zmnhld.json
2025-01-10 22:05:04 -08:00

633 lines
11 KiB
JSON

{
"manufacturer": "Qubino",
"manufacturerId": "0x0159",
"label": "ZMNHLD",
"description": "Flush PWM Thermostat",
"devices": [
{
"productType": "0x0005",
"productId": "0x0053"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Input I1 Switch Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Mono-Stable switch type",
"value": 0
},
{
"label": "Bi-Stable switch type",
"value": 1
}
]
},
{
"#": "2",
"label": "Input I2 Switch Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Mono-Stable switch type",
"value": 0
},
{
"label": "Bi-Stable switch type",
"value": 1
}
]
},
{
"#": "3",
"label": "Input I3 Switch Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Mono-Stable switch type (Push button)",
"value": 0
},
{
"label": "Bi-Stable switch type",
"value": 1
}
]
},
{
"#": "4",
"label": "Input 1 Contact Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Normally open",
"value": 0
},
{
"label": "Normally closed",
"value": 1
}
]
},
{
"#": "5",
"label": "Input 2 Contact Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Normally open",
"value": 0
},
{
"label": "Normally closed",
"value": 1
}
]
},
{
"#": "6",
"label": "Input 3 Contact Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Normally open",
"value": 0
},
{
"label": "Normally closed",
"value": 1
}
]
},
{
"#": "10",
"label": "Activate / Deactivate ALL ON/ALL OFF",
"valueSize": 2,
"defaultValue": 255,
"allowManualEntry": false,
"options": [
{
"label": "All on is not active / All off is not active",
"value": 0
},
{
"label": "All on is not active / All off is active",
"value": 1
},
{
"label": "All on is active / All off is not active",
"value": 2
},
{
"label": "All on is active / All off is active",
"value": 255
}
]
},
{
"#": "11",
"label": "I1 Functionality Selection",
"valueSize": 2,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Input I1 changes between off and heat/cool",
"value": 1
},
{
"label": "Input I1 influences the heating/cooling valves",
"value": 2
},
{
"label": "No influence on the heat/cool process",
"value": 32767
}
]
},
{
"#": "12",
"label": "I2 Functionality Selection",
"valueSize": 2,
"defaultValue": 32767,
"allowManualEntry": false,
"options": [
{
"label": "Input I2 influences the cooling value",
"value": 2000
},
{
"label": "Input I2 doesn't influence on the heat/cool process",
"value": 32767
}
]
},
{
"#": "13",
"label": "I3 Functionality Selection",
"valueSize": 2,
"defaultValue": 32767,
"allowManualEntry": false,
"options": [
{
"label": "Input I3 changes the mode of the thermostat",
"value": 1
},
{
"label": "Input I3 influences on heating/cooling valves",
"value": 2
},
{
"label": "Does not influence on the heat/cool process",
"value": 32767
}
]
},
{
"#": "40",
"label": "Power Reporting in Watts on Power Change",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 100,
"defaultValue": 0,
"options": [
{
"label": "Power consumption reporting disabled",
"value": 0
}
]
},
{
"#": "42",
"label": "Power Reporting in Watts by Time Interval",
"valueSize": 2,
"minValue": 0,
"maxValue": 32767,
"defaultValue": 0
},
{
"#": "45",
"label": "Antifreeze",
"valueSize": 2,
"minValue": 0,
"maxValue": 1127,
"defaultValue": 50
},
{
"#": "50",
"label": "PWM Maximum Value",
"valueSize": 1,
"unit": "%",
"minValue": 2,
"maxValue": 100,
"defaultValue": 100
},
{
"#": "51",
"label": "PWM Minimum Value",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 0
},
{
"#": "52",
"label": "PWM Cycle Duration",
"valueSize": 1,
"unit": "seconds",
"minValue": 5,
"maxValue": 127,
"defaultValue": 10
},
{
"#": "53",
"label": "PID Value Inside Deadband",
"valueSize": 1,
"minValue": 0,
"maxValue": 127,
"defaultValue": 0
},
{
"#": "54",
"label": "PID Deadband",
"valueSize": 1,
"unit": "°C",
"minValue": 0,
"maxValue": 127,
"defaultValue": 5
},
{
"#": "55",
"label": "Integral Sampling Time",
"valueSize": 1,
"unit": "seconds",
"minValue": 0,
"maxValue": 127,
"defaultValue": 5
},
{
"#": "56",
"label": "P Parameter",
"valueSize": 2,
"minValue": 0,
"maxValue": 1000,
"defaultValue": 100
},
{
"#": "57",
"label": "I Parameter",
"valueSize": 2,
"minValue": 0,
"maxValue": 1000,
"defaultValue": 1
},
{
"#": "58",
"label": "D Parameter",
"valueSize": 2,
"minValue": 0,
"maxValue": 1000,
"defaultValue": 0
},
{
"#": "59",
"label": "Thermostat Mode",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Heat mode",
"value": 0
},
{
"label": "Cool mode",
"value": 1
}
]
},
{
"#": "60",
"label": "Too Low Temperature Limit",
"valueSize": 2,
"unit": "°C",
"minValue": 1,
"maxValue": 1150,
"defaultValue": 50
},
{
"#": "61",
"label": "Too High Temperature Limit",
"valueSize": 2,
"unit": "°C",
"minValue": 1,
"maxValue": 1000,
"defaultValue": 700
},
{
"#": "63",
"label": "Output Switch Selection",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "When system is turned off the output is 0V(NC)",
"value": 0
},
{
"label": "System off the output is 230V or 24V(NO)",
"value": 1
}
]
},
{
"#": "70",
"label": "Input I1 Status on Delay",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "71",
"label": "Input I1 Status Off Delay",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "72",
"label": "Input I2 Status on Delay",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "73",
"label": "Input I2 Status Off Delay",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "74",
"label": "Input 3 Status ON Delay",
"valueSize": 2,
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "75",
"label": "Input I3 Status Off Delay",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "76",
"label": "Reporting on Time Interval",
"valueSize": 1,
"unit": "minutes",
"minValue": 0,
"maxValue": 127,
"defaultValue": 30
},
{
"#": "77",
"label": "Group 10 - Delay Before Sending Basic Set ON",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 180
},
{
"#": "78",
"label": "Scale Selection",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Degrees celsius",
"value": 0
},
{
"label": "Degrees fahrenheit",
"value": 1
}
]
},
{
"#": "100",
"label": "Enable/Disable I1 or Select Type and Event",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "Home security, motion detection",
"value": 1
},
{
"label": "CO - Carbon monoxid detected",
"value": 2
},
{
"label": "CO2 - Carbon dioxid detected",
"value": 3
},
{
"label": "Water alarm",
"value": 4
},
{
"label": "Heat alarm",
"value": 5
},
{
"label": "Smoke alarm",
"value": 6
},
{
"label": "Binary Sensor",
"value": 9
}
]
},
{
"#": "101",
"label": "Enable/Disable Endpoint I2 or Select Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "Home security, motion detection",
"value": 1
},
{
"label": "CO - Carbon monoxid detected",
"value": 2
},
{
"label": "CO2 - Carbon dioxid detected",
"value": 3
},
{
"label": "Water alarm",
"value": 4
},
{
"label": "Heat alarm",
"value": 5
},
{
"label": "Smoke alarm",
"value": 6
},
{
"label": "Binary Sensor",
"value": 9
}
]
},
{
"#": "102",
"label": "Enable/Disable Endpoint I3 or Select Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "Home security, motion detection",
"value": 1
},
{
"label": "CO - Carbon monoxid detected",
"value": 2
},
{
"label": "CO2 - Carbon dioxid detected",
"value": 3
},
{
"label": "Water alarm",
"value": 4
},
{
"label": "Heat alarm",
"value": 5
},
{
"label": "Smoke alarm",
"value": 6
},
{
"label": "Binary Sensor",
"value": 9
}
]
},
{
"#": "110",
"label": "Temperature Sensor Offset Settings",
"valueSize": 2,
"unit": "°C",
"minValue": 0,
"maxValue": 32536,
"defaultValue": 32536
},
{
"#": "120",
"label": "Digital Temperature Sensor Reporting",
"valueSize": 1,
"minValue": 0,
"maxValue": 127,
"defaultValue": 5
},
{
"#": "121",
"label": "Digital Temperature Sensor / Setpoint Selector",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Internal sensor is mounted",
"value": 0
},
{
"label": "Temperature is grabbed by sensor with assoc 3",
"value": 1
},
{
"label": "Temperature is grabbed from ext battery sensor",
"value": 2
},
{
"label": "Setpoint is grabbed by sensor with assoc 5",
"value": 4
},
{
"label": "Setpoint is grabbed from ext battery sensor",
"value": 8
},
{
"label": "Temperature & setpoint from ext batt sensor",
"value": 10
}
]
},
{
"#": "122",
"label": "Node Id of External Battery Powered Sensor",
"valueSize": 1,
"minValue": 0,
"maxValue": 254,
"defaultValue": 0,
"unsigned": true
}
]
}