zwave-js/.config-db/devices/0x0159/zmnhad.json
2025-01-10 22:05:04 -08:00

276 lines
5.3 KiB
JSON

{
"manufacturer": "Qubino",
"manufacturerId": "0x0159",
"label": "ZMNHAD",
"description": "Flush 1 Relay",
"devices": [
{
"productType": "0x0002",
"productId": "0x0052"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Input 1 Switch Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Mono-Stable switch type (Push button)",
"value": 0
},
{
"label": "Bi-Stable switch type",
"value": 1
}
]
},
{
"#": "2",
"label": "Input 2 Contact Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "NO (Normally open) input type",
"value": 0
},
{
"label": "NC (Normally close) input type",
"value": 1
}
]
},
{
"#": "3",
"label": "Input 3 Contact Type",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "NO (Normally open) input type",
"value": 0
},
{
"label": "NC (Normally close) input type",
"value": 1
}
]
},
{
"#": "10",
"label": "Activate /Deactivate ALL ON/ALL OFF",
"description": "module responds to commands ALL ON / ALL OFF",
"valueSize": 1,
"defaultValue": 255,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "All on is not active all off is not active",
"value": 0
},
{
"label": "All on is not active all off active",
"value": 1
},
{
"label": "All on active all off is not active",
"value": 2
},
{
"label": "All on active, all off active",
"value": 255
}
]
},
{
"#": "11",
"label": "Automatic Turning Off Relay After Set Time",
"description": "When relay goes automatically OFF after this time",
"valueSize": 2,
"minValue": 0,
"maxValue": 32535,
"defaultValue": 0
},
{
"#": "12",
"label": "Automatic Turning on Relay After Set Time",
"description": "When relay goes automatically ON after this time",
"valueSize": 2,
"minValue": 0,
"maxValue": 32535,
"defaultValue": 0
},
{
"#": "15",
"label": "Automatic Switching Units Selection",
"description": "NOTE: Parameter is the same for turning OFF or ON.",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Seconds selected",
"value": 0
},
{
"label": "Milliseconds selected",
"value": 1
}
]
},
{
"#": "30",
"$import": "~/templates/master_template.json#state_after_power_failure_prev_off"
},
{
"#": "40",
"label": "Power Reporting in Watts on Power Change",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 10
},
{
"#": "42",
"label": "Power Reporting in Watts by Time Interval",
"description": "Set value means time interval when power report is send",
"valueSize": 2,
"minValue": 0,
"maxValue": 32535,
"defaultValue": 300
},
{
"#": "63",
"label": "Output Switch Selection",
"description": "Set the type of the device connected to the output. (NO) / (NC)",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "0V (NC)",
"value": 0
},
{
"label": "230V or 240V (NO)",
"value": 1
}
]
},
{
"#": "100",
"label": "Endpoints I2 Notification Type and Event",
"description": "After changing this parameter, the device MUST be excluded and then re-included after waiting 30 seconds.",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Endpoint, I2 disabled",
"value": 0
},
{
"label": "Home security",
"value": 1
},
{
"label": "Carbon monoxide",
"value": 2
},
{
"label": "Carbon dioxide",
"value": 3
},
{
"label": "Water alarm",
"value": 4
},
{
"label": "Heat alarm",
"value": 5
},
{
"label": "Smoke alarm",
"value": 6
},
{
"label": "Binary Sensor",
"value": 9
}
]
},
{
"#": "101",
"label": "Endpoints I3 Notification Type and Event",
"description": "After changing this parameter, the device MUST be excluded and then re-included after waiting 30 seconds.",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Endpoint, I3 disabled",
"value": 0
},
{
"label": "Home security",
"value": 1
},
{
"label": "Carbon monoxide",
"value": 2
},
{
"label": "Carbon dioxide",
"value": 3
},
{
"label": "Water alarm",
"value": 4
},
{
"label": "Heat alarm",
"value": 5
},
{
"label": "Smoke alarm",
"value": 6
},
{
"label": "Binary Sensor",
"value": 9
}
]
},
{
"#": "110",
"label": "Temperature Sensor Offset Settings",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 32536,
"unsigned": true
},
{
"#": "120",
"label": "Digital Temperature Sensor Reporting",
"valueSize": 1,
"minValue": 0,
"maxValue": 127,
"defaultValue": 5
}
],
"compat": {
// The device has user-configurable endpoints. We shouldn't hide them
"preserveEndpoints": "*"
}
}