"manufacturer": "Qubino",
|
|
"manufacturerId": "0x0159",
|
|
"label": "ZMNHAD",
|
|
"description": "Flush 1 Relay",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0002",
|
|
"productId": "0x0052"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Input 1 Switch Type",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Mono-Stable switch type (Push button)",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Bi-Stable switch type",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Input 2 Contact Type",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "NO (Normally open) input type",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "NC (Normally close) input type",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Input 3 Contact Type",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "NO (Normally open) input type",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "NC (Normally close) input type",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "10",
|
|
"label": "Activate /Deactivate ALL ON/ALL OFF",
|
|
"description": "module responds to commands ALL ON / ALL OFF",
|
|
"valueSize": 1,
|
|
"defaultValue": 255,
|
|
"unsigned": true,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "All on is not active all off is not active",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "All on is not active all off active",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "All on active all off is not active",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "All on active, all off active",
|
|
"value": 255
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "11",
|
|
"label": "Automatic Turning Off Relay After Set Time",
|
|
"description": "When relay goes automatically OFF after this time",
|
|
"valueSize": 2,
|
|
"minValue": 0,
|
|
"maxValue": 32535,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "12",
|
|
"label": "Automatic Turning on Relay After Set Time",
|
|
"description": "When relay goes automatically ON after this time",
|
|
"valueSize": 2,
|
|
"minValue": 0,
|
|
"maxValue": 32535,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "15",
|
|
"label": "Automatic Switching Units Selection",
|
|
"description": "NOTE: Parameter is the same for turning OFF or ON.",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Seconds selected",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Milliseconds selected",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "30",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_prev_off"
|
|
},
|
|
{
|
|
"#": "40",
|
|
"label": "Power Reporting in Watts on Power Change",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 10
|
|
},
|
|
{
|
|
"#": "42",
|
|
"label": "Power Reporting in Watts by Time Interval",
|
|
"description": "Set value means time interval when power report is send",
|
|
"valueSize": 2,
|
|
"minValue": 0,
|
|
"maxValue": 32535,
|
|
"defaultValue": 300
|
|
},
|
|
{
|
|
"#": "63",
|
|
"label": "Output Switch Selection",
|
|
"description": "Set the type of the device connected to the output. (NO) / (NC)",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "0V (NC)",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "230V or 240V (NO)",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "100",
|
|
"label": "Endpoints I2 Notification Type and Event",
|
|
"description": "After changing this parameter, the device MUST be excluded and then re-included after waiting 30 seconds.",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Endpoint, I2 disabled",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Home security",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Carbon monoxide",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Carbon dioxide",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "Water alarm",
|
|
"value": 4
|
|
},
|
|
{
|
|
"label": "Heat alarm",
|
|
"value": 5
|
|
},
|
|
{
|
|
"label": "Smoke alarm",
|
|
"value": 6
|
|
},
|
|
{
|
|
"label": "Binary Sensor",
|
|
"value": 9
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "101",
|
|
"label": "Endpoints I3 Notification Type and Event",
|
|
"description": "After changing this parameter, the device MUST be excluded and then re-included after waiting 30 seconds.",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Endpoint, I3 disabled",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Home security",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Carbon monoxide",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Carbon dioxide",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "Water alarm",
|
|
"value": 4
|
|
},
|
|
{
|
|
"label": "Heat alarm",
|
|
"value": 5
|
|
},
|
|
{
|
|
"label": "Smoke alarm",
|
|
"value": 6
|
|
},
|
|
{
|
|
"label": "Binary Sensor",
|
|
"value": 9
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "110",
|
|
"label": "Temperature Sensor Offset Settings",
|
|
"valueSize": 2,
|
|
"minValue": 0,
|
|
"maxValue": 65535,
|
|
"defaultValue": 32536,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "120",
|
|
"label": "Digital Temperature Sensor Reporting",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 127,
|
|
"defaultValue": 5
|
|
}
|
|
],
|
|
"compat": {
|
|
// The device has user-configurable endpoints. We shouldn't hide them
|
|
"preserveEndpoints": "*"
|
|
}
|
|
}
|