"manufacturer": "wiDom",
"manufacturerId": "0x0149",
"label": "WDS2",
"description": "Universal Double Switch",
"devices": [
{
"productType": "0x1214",
"productId": "0x0b00"
},
{
"productType": "0x1214",
"productId": "0x0c00"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Numbers of Clicks to Control Channel 1",
"description": "Define which sequences of clicks control the load connected to Channel 1/2.",
"valueSize": 1,
"defaultValue": 7,
"allowManualEntry": false,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "ONE_CLICK",
"value": 1
},
{
"label": "TWO_CLICKS",
"value": 2
},
{
"label": "ONE_CLICK or TWO_CLICKS",
"value": 3
},
{
"label": "THREE_CLICKS",
"value": 4
},
{
"label": "ONE_CLICK or THREE_CLICKS",
"value": 5
},
{
"label": "TWO_CLICKS or THREE_CLICKS",
"value": 6
},
{
"label": "ONE_CLICK, TWO_CLICKS or THREE_CLICKS",
"value": 7
}
]
},
{
"#": "2",
"label": "Numbers of Clicks to Control Channel 2",
"description": "Define which sequences of click control the load connected to Channel 2",
"valueSize": 1,
"defaultValue": 8,
"allowManualEntry": false,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "ONE_CLICK",
"value": 1
},
{
"label": "TWO_CLICKS",
"value": 2
},
{
"label": "ONE_CLICK or TWO_CLICKS",
"value": 3
},
{
"label": "THREE_CLICKS",
"value": 4
},
{
"label": "ONE_CLICK or THREE_CLICKS",
"value": 5
},
{
"label": "TWO_CLICKS or THREE_CLICKS",
"value": 6
},
{
"label": "ONE_CLICK, TWO_CLICKS or THREE_CLICKS",
"value": 7
},
{
"label": "EQUAL_TO_CHANNEL_1",
"value": 8
}
]
},
{
"#": "4",
"label": "Value Used for Devices Belonging to Group 2",
"valueSize": 1,
"defaultValue": 100,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Basic Set on",
"value": 255
},
{
"label": "Basic Set off",
"value": 0
},
{
"label": "Basic Set with same value of channel status",
"value": 100
}
]
},
{
"#": "5",
"label": "Value Used for Devices Belonging to Group 5",
"valueSize": 1,
"defaultValue": 100,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Basic Set on",
"value": 255
},
{
"label": "Basic Set off",
"value": 0
},
{
"label": "Basic Set with same value of channel status",
"value": 100
}
]
},
{
"#": "6",
"label": "Value Used for Devices Belonging to Group 3",
"valueSize": 1,
"defaultValue": 100,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Basic Set on",
"value": 255
},
{
"label": "Basic Set off",
"value": 0
},
{
"label": "Basic Set with same value of channel status",
"value": 100
}
]
},
{
"#": "7",
"label": "Value Used for Devices Belonging to Group 6",
"valueSize": 1,
"defaultValue": 100,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Basic Set on",
"value": 255
},
{
"label": "Basic Set off",
"value": 0
},
{
"label": "Basic Set with same value of channel status",
"value": 100
}
]
},
{
"#": "8",
"label": "Value Used for Devices Belonging to Group 4",
"valueSize": 1,
"defaultValue": 100,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Basic Set on",
"value": 255
},
{
"label": "Basic Set off",
"value": 0
},
{
"label": "Basic Set with same value of channel status",
"value": 100
}
]
},
{
"#": "9",
"label": "Value Used for Devices Belonging to Group 7",
"valueSize": 1,
"defaultValue": 100,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Basic Set on",
"value": 255
},
{
"label": "Basic Set off",
"value": 0
},
{
"label": "Basic Set with same value of channel status",
"value": 100
}
]
},
{
"#": "10",
"label": "Timer to Switch OFF the Channel 1",
"description": "Defines the time after which the Channel 1 is switched OFF",
"valueSize": 2,
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "11",
"label": "Timer to Switch OFF the Channel 2",
"description": "Defines the time after which the Channel 2 is switched OFF",
"valueSize": 2,
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "12",
"label": "Timer to Switch ON the Channel 1",
"description": "Defines the time after which the Channel 1 is switched ON",
"valueSize": 2,
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "13",
"label": "Timer to Switch ON the Channel 2",
"description": "Defines the time after which the Channel 2 is switched ON",
"valueSize": 2,
"minValue": 0,
"maxValue": 32000,
"defaultValue": 0
},
{
"#": "40",
"label": "Local Scenario",
"description": "Defines the behavior of the device Channels",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "INDIPENDENT_CHANNELS",
"value": 0
},
{
"label": "NEVER_BOTH_ON",
"value": 1
},
{
"label": "SEQUENCING_RELAY",
"value": 2
}
]
},
{
"#": "60",
"label": "Start-Up Status",
"description": "Defines the status of the device following a restart.",
"valueSize": 1,
"defaultValue": 4,
"allowManualEntry": false,
"options": [
{
"label": "OFF_OFF - Both channel 1 and channel 2 off",
"value": 0
},
{
"label": "OFF_ON - Channel 1 off, channel 2 on",
"value": 1
},
{
"label": "ON_OFF - Channel 1 on, channel 2 off",
"value": 2
},
{
"label": "ON_ON - Both channel 1 and channel 2 on",
"value": 3
},
{
"label": "Previous status - Status prior to restart",
"value": 4
}
]
},
{
// This parameter is undocumented (the same as for the WDS)
"#": "61",
"label": "Configuration Reset",
"description": "Defines which parameters should be reset to default values",
"valueSize": 1,
"defaultValue": 4,
"allowManualEntry": false,
"options": [
{
"label": "Factory reset",
"value": 0
},
{
"label": "Associations reset",
"value": 1
},
{
"label": "Configurations reset",
"value": 2
},
{
"label": "Restart device",
"value": 3
},
{
"label": "Ignore",
"value": 4
}
]
},
{
"#": "62",
"label": "Type of External Switch Both Inputs",
"description": "Defines the type of external switch connected both to input 1 and input 2.",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Ignore",
"value": 0
},
{
"label": "Button",
"value": 1
},
{
"label": "Switch",
"value": 2
}
]
},
{
"#": "63",
"label": "Type of External Switch Input 2",
"description": "Define the switch type connected to the input 2",
"valueSize": 1,
"defaultValue": 3,
"allowManualEntry": false,
"options": [
{
"label": "Ignore",
"value": 0
},
{
"label": "Button",
"value": 1
},
{
"label": "Switch",
"value": 2
},
{
"label": "Equal to switch 1",
"value": 3
}
]
}
]
}