"manufacturer": "Philio Technology Corp",
|
|
"manufacturerId": "0x013c",
|
|
"label": "PAD15",
|
|
"description": "2 Wire Dimmer",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0005",
|
|
"productId": "0x007e",
|
|
"zwaveAllianceId": [4209, 4216, 4217, 4248, 4256, 4257, 4261, 4264, 4268]
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Switch Set",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Enable S1",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable S1 & S2",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Dimmer up/down",
|
|
"value": 2
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on"
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Send Multilevel Switch Reports",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Maximum Level",
|
|
"valueSize": 1,
|
|
"minValue": 1,
|
|
"maxValue": 99,
|
|
"defaultValue": 99
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "Minimum Level",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 98,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Basic Duration Set",
|
|
"valueSize": 1,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 127,
|
|
"defaultValue": 2
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "Add(Classic Inclusion) : 1. Put your Z-Wave™ controller into inclusion mode by following the instructions\nprovided by the controller manufacturer. 2. Press the include button three times within 3 seconds to enter\ninclusion mode",
|
|
"exclusion": "Remove (Exclusion) 1. Put your Z-Wave™ controller into exclusion mode by following the instructions\nprovided by the controller manufacturer. 2. Press the include button three times within 3 seconds to enter\nexclusion mode. 3. Node ID will be excluded",
|
|
"reset": "Reset : 1. Press the include button four times within 3 seconds and hold on the button press without\nreleasing. 2. Keep pressing the button for 3 seconds then LED will be o ,release the button within 2 seconds.\n3. Device has been reset. ※Function Reset : Please use this procedure only when the network primary\ncontroller is missing or otherwise inoperable",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4209/PAD15_UserManual_V3.pdf"
|
|
}
|
|
}
|