"manufacturer": "Zipato",
"manufacturerId": "0x0131",
"label": "PSP02",
"description": "Door/temp/illumination/motion Sensor",
"devices": [
{
"productType": "0x0002",
"productId": "0x000c"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "2",
"label": "Basic Set Level",
"description": "Basic command to turn on the light",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 255,
"unsigned": true,
"options": [
{
"label": "Off",
"value": 0
},
{
"label": "On",
"value": 255
}
]
},
{
"#": "3",
"label": "PIR Sensitivity",
"description": "setting",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 80
},
{
"#": "4",
"label": "Light Threshold",
"description": "setting",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 99
},
{
"#": "8",
"label": "PIR Motion Re-Trigger Min Interval",
"valueSize": 1,
"unit": "8s ticks",
"minValue": 0,
"maxValue": 127,
"defaultValue": 3
},
{
"#": "9",
"label": "Light on Time Hysteresis",
"description": "time to keep the light on without motion",
"valueSize": 1,
"unit": "8s ticks",
"minValue": 0,
"maxValue": 127,
"defaultValue": 4
},
{
"#": "10",
"label": "Battery Level Auto-Report Interval",
"valueSize": 1,
"unit": "ticks",
"minValue": 0,
"maxValue": 127,
"defaultValue": 12
},
{
"#": "11",
"label": "Door State Report Interval",
"valueSize": 1,
"unit": "ticks",
"minValue": 0,
"maxValue": 127,
"defaultValue": 12
},
{
"#": "12",
"label": "Illumination Auto Report Interval",
"valueSize": 1,
"unit": "ticks",
"minValue": 0,
"maxValue": 127,
"defaultValue": 12
},
{
"#": "13",
"label": "Temperature Report Interval",
"valueSize": 1,
"unit": "ticks",
"minValue": 0,
"maxValue": 127,
"defaultValue": 12
},
{
"#": "20",
"label": "Tick Duration",
"description": "auto-reports tick duration",
"valueSize": 1,
"unit": "seconds",
"minValue": 0,
"maxValue": 255,
"defaultValue": 30,
"unsigned": true
},
{
"#": "21",
"label": "Temperature Differential to Report",
"valueSize": 1,
"unit": "Fahrenheit",
"minValue": 0,
"maxValue": 127,
"defaultValue": 1
},
{
"#": "22",
"label": "Min Illumination Differential",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 63,
"defaultValue": 0
},
{
"#": "5[0x02]",
"label": "Operation Mode",
"description": "set test mode if DIP switch in customer mode",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Normal mode",
"value": 0
},
{
"label": "Test mode",
"value": 1
}
]
},
{
"#": "5[0x04]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Door/window Function",
"defaultValue": 0
},
{
"#": "5[0x08]",
"label": "Temperature Unit",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Fahrenheit",
"value": 0
},
{
"label": "Celsius",
"value": 1
}
]
},
{
"#": "5[0x10]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Illumination Reports",
"defaultValue": 0
},
{
"#": "5[0x20]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Temperature Reports",
"defaultValue": 0
},
{
"#": "5[0x80]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Back Key Release Action",
"description": "Disable/enable the back key release into test mode",
"defaultValue": 0
},
{
"#": "6[0x01]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Magnetic Integration for Lighting Control",
"description": "Switch control",
"defaultValue": 0
},
{
"#": "6[0x02]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "PIR Integration to Control Lighting",
"description": "PIR integration",
"defaultValue": 0
},
{
"#": "6[0x04]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Magetic/pir Integration",
"description": "control lighting in association group 2"
},
{
"#": "6[0x08]",
"label": "Device and Lighting in Same Room",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Same room",
"value": 0
},
{
"label": "Different rooms",
"value": 1
}
]
},
{
"#": "6[0x10]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Delay to Turn Off the Light",
"description": "disable/enable delay",
"defaultValue": 0
},
{
"#": "6[0x20]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Light Off Control",
"description": "disable/enable auto turn off the light",
"defaultValue": 0
},
{
"#": "7[0x02]",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Motion Off Report"
},
{
"#": "7[0x04]",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "PIR Super-Sensitivity",
"defaultValue": 1
},
{
"#": "7[0x08]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "BASIC OFF Report",
"description": "Disable/enable report after door closed",
"defaultValue": 0
},
{
"#": "7[0x10]",
"label": "Door Closed Report Type",
"description": "notification or Binary Sensor report",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Notification Report",
"value": 0
},
{
"label": "Binary Sensor Report",
"value": 1
}
]
},
{
"#": "7[0x20]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Multi CC in Auto Report",
"description": "disable/enable multi CC in report",
"defaultValue": 0
},
{
"#": "7[0x40]",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Battery State Reports",
"defaultValue": 0
}
]
}