zwave-js/.config-db/devices/0x0129/yrl216.json
2025-01-10 22:05:04 -08:00

61 lines
2 KiB
JSON

{
"manufacturer": "Yale",
"manufacturerId": "0x0129",
"label": "YRL216 / YRL236",
"description": "Assure Lever Keypad with Z-Wave Plus",
"devices": [
{
"productType": "0x800b",
"productId": "0x0f00",
"zwaveAllianceId": [3129, 3266]
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"$import": "templates/yale_template.json#volume"
},
{
"#": "2",
"$import": "templates/yale_template.json#auto_relock"
},
{
"#": "3",
"$import": "templates/yale_template.json#auto_relock_time_180"
},
{
"#": "4",
"$import": "templates/yale_template.json#wrong_code_limit_3_to_10"
},
{
"#": "7",
"$import": "templates/yale_template.json#wrong_code_lockout_10_to_127"
},
{
"#": "8",
"$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
},
{
"#": "11",
"$import": "templates/yale_template.json#one_touch"
},
{
"#": "13",
"$import": "templates/yale_template.json#lock_status_led"
},
{
"#": "15",
"$import": "templates/yale_template.json#reset_factory"
}
],
"metadata": {
"inclusion": "To include; Enter the 4-8 master Pin code followed by the gear key.\nPress the 7 key followed by the gear key\nPress the 1 key followed by the gear key",
"exclusion": "To exclude; Enter the 4-8 digit master pin code followed by the gear key\nPress the 7 key followed by the gear key\nPress the 3 key followed by the gear key",
"reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3129/Assure_Lever_Manual_ZWave_Cert.pdf"
}
}