76 lines
2.5 KiB
JSON
76 lines
2.5 KiB
JSON
{
|
|
"manufacturer": "Vision Security",
|
|
"manufacturerId": "0x0109",
|
|
"label": "ZD2301EU-5",
|
|
"description": "4 in 1 Door Sensor",
|
|
"devices": [
|
|
{
|
|
"productType": "0x201f",
|
|
"productId": "0x1f20",
|
|
"zwaveAllianceId": 1334
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Temperature Unit",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Celsius",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Fahrenheit",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Temperature Report Threshold",
|
|
"valueSize": 1,
|
|
"unit": "0.1 (°C/°F)",
|
|
"minValue": 1,
|
|
"maxValue": 50,
|
|
"defaultValue": 10
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Humidity Report Threshold",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 1,
|
|
"maxValue": 50,
|
|
"defaultValue": 10
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Luminance Report Threshold",
|
|
"description": "Allowable range: 0, 5-50",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 50,
|
|
"defaultValue": 10,
|
|
"options": [
|
|
{
|
|
"label": "Disabled",
|
|
"value": 0
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "4. For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the ZD2301 to your controller. To get in the “inclusion” mode, the distance between sensor and controller is suggested to be in one meter. Press the program switch of ZD2301 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2301 will go to sleep after 20 seconds",
|
|
"exclusion": "5. For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to delete the ZD2301 from your controller. Press the program switch of ZD2301 for 1 second at least to be excluded.\nNote: All user and network settings will be cleared and the device reset to factory defaults when the device is excluded.",
|
|
"reset": "Factory Default Reset: \n*Open the rear cover to send the Alarm Report and then press the program switch 10 times in 10 seconds, ZD2301 will send the “Device Reset Locally” command and reset to the factory default. \n*Please use this procedure only in the event that the network primary controller is missing or otherwise inoperable",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1334/ZD%202301-5_20150603.pdf"
|
|
}
|
|
}
|