"manufacturer": "Diehl AKO",
|
|
"manufacturerId": "0x0103",
|
|
"label": "SES FS-ZW",
|
|
"description": "Plug Actuator",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0001",
|
|
"productId": "0x0002",
|
|
"zwaveAllianceId": 737
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"associations": {
|
|
"1": {
|
|
"label": "Group 1",
|
|
"maxNodes": 1,
|
|
"isLifeline": true
|
|
}
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev"
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Energy Minimum Report Time",
|
|
"description": "Minimum time between two (non-requested) energy values",
|
|
"valueSize": 2,
|
|
"unit": "1s",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 10
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Energy Maximum Report Time",
|
|
"description": "Maximum time between two energy values, independently of changes in the value",
|
|
"valueSize": 2,
|
|
"unit": "1s",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 120
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Power Minimum Report Time",
|
|
"description": "Minimum time between two (non-requested) power values",
|
|
"valueSize": 2,
|
|
"unit": "1s",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 10
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "Power Maximum Report Time",
|
|
"description": "Maximum time between two power values, independently of changes in the value",
|
|
"valueSize": 2,
|
|
"unit": "1s",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 120
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Energy Delta Value",
|
|
"description": "Minimum change required for a new energy value to be transmitted.",
|
|
"valueSize": 2,
|
|
"unit": "0.1 Wh",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 10
|
|
},
|
|
{
|
|
"#": "7",
|
|
"label": "Power Delta Value",
|
|
"description": "Minimum change required for a new power value to be transmitted.",
|
|
"valueSize": 2,
|
|
"unit": "0.1 Wh",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 150
|
|
},
|
|
{
|
|
"#": "8",
|
|
"label": "Safety Shutdown Configuration",
|
|
"description": "Behaviour in the event of a safety shutdown",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Plug actuator remains off",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Automatic restart",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "9",
|
|
"label": "Reset of Overcurrent Shutdown",
|
|
"description": "Activation despite 3x safety shutdown",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"writeOnly": true,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "No reset",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Reset",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "10",
|
|
"label": "Night Mode",
|
|
"description": "Set Night mode of the Status LED",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Night mode off",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Night mode on",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "11",
|
|
"label": "Info LED Colour",
|
|
"description": "Set color of the Info LED",
|
|
"valueSize": 2,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Info LED off",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Info LED green",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Info LED yellow",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Info LED red",
|
|
"value": 3
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|