zwave-js/.config-db/devices/0x0098/ct32.json
2025-01-10 22:05:04 -08:00

179 lines
3.3 KiB
JSON

{
"manufacturer": "Radio Thermostat Company of America (RTC)",
"manufacturerId": "0x0098",
"label": "CT32",
"description": "Z-Wave Thermostat",
"devices": [
{
"productType": "0x0002",
"productId": "0x0100"
},
{
"productType": "0x2002",
"productId": "0x0100",
"zwaveAllianceId": [1046, 1330]
},
{
"productType": "0x2002",
"productId": "0x0102"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Temperature Reporting Threshold",
"description": "Sets the reporting threshold for changes in ambient temperature.",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "0.5 °F",
"value": 1
},
{
"label": "1.0 °F",
"value": 2
},
{
"label": "1.5 °F",
"value": 3
},
{
"label": "2.0 °F",
"value": 4
}
]
},
{
"#": "3",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Utility Lock",
"description": "Enables or Disables the Utility Lock."
},
{
"#": "5",
"label": "Humidity Reporting Threshold",
"description": "Sets the reporting threshold for changes in humidity.",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "3 %rH",
"value": 1
},
{
"label": "5 %rH",
"value": 2
},
{
"label": "10 %rH",
"value": 3
}
]
},
{
"#": "6",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Auxiliary/Emergency Heat",
"description": "Enables or Disables the Aux / Emergency Heat."
},
{
"#": "7",
"label": "Swing Temperature",
"description": "Sets the swing threshold before turning on / off HVAC.",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "0.0 °F",
"value": 1
},
{
"label": "1.0 °F",
"value": 2
},
{
"label": "1.5 °F",
"value": 3
},
{
"label": "2.0 °F",
"value": 4
},
{
"label": "2.5 °F",
"value": 5
},
{
"label": "3.0 °F",
"value": 6
},
{
"label": "3.5 °F",
"value": 7
},
{
"label": "4.0 °F",
"value": 8
}
]
},
{
"#": "8",
"label": "Thermostat Diff Temperature",
"description": "Set's the differential temperature for multi-stage HVAC systems.",
"valueSize": 2,
"minValue": 4,
"maxValue": 3084,
"defaultValue": 4
},
{
"#": "9",
"label": "Thermostat Recovery Mode",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Fast",
"value": 1
},
{
"label": "Economy",
"value": 2
}
]
},
{
"#": "11",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Simple UI Mode",
"defaultValue": 1
},
{
"#": "12",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Multicast"
}
],
"compat": {
// The device has two endpoints, but all reports are received via the root.
"preserveRootApplicationCCValueIDs": true,
"removeEndpoints": "*"
}
}