"manufacturer": "Radio Thermostat Company of America (RTC)",
"manufacturerId": "0x0098",
"label": "CT101",
"description": "Z-Wave Thermostat",
"devices": [
{
"productType": "0x6501",
"productId": "0x0000",
"zwaveAllianceId": 1301
},
{
"productType": "0x6501",
"productId": "0x000b"
},
{
"productType": "0x6501",
"productId": "0x000c"
},
{
"productType": "0x6501",
"productId": "0x000d"
},
{
"productType": "0x6501",
"productId": "0x00fd"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 2,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"label": "Temperature Reporting Threshold",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "0.5 °F",
"value": 1
},
{
"label": "1.0 °F",
"value": 2
},
{
"label": "1.5 °F",
"value": 3
},
{
"label": "2.0 °F",
"value": 4
}
]
},
{
"#": "2[0xff000000]",
"label": "HVAC Type",
"valueSize": 4,
"defaultValue": 1,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Normal",
"value": 1
},
{
"label": "Heat pump",
"value": 2
}
]
},
{
"#": "2[0x0f0000]",
"label": "Number of Auxiliary or Heat Stages",
"valueSize": 4,
"minValue": 0,
"maxValue": 15,
"unsigned": true,
"readOnly": true,
"allowManualEntry": false
},
{
"#": "2[0xf00000]",
"label": "Auxiliary Heat Type",
"valueSize": 4,
"unsigned": true,
"readOnly": true,
"allowManualEntry": false,
"options": [
{
"label": "Gas",
"value": 1
},
{
"label": "Electric",
"value": 2
}
]
},
{
"#": "2[0xff00]",
"label": "Number of Heat Pump Stages",
"valueSize": 4,
"minValue": 0,
"maxValue": 255,
"unsigned": true,
"readOnly": true,
"allowManualEntry": false
},
{
"#": "2[0xff]",
"label": "Number of Cool Stages",
"valueSize": 4,
"minValue": 0,
"maxValue": 255,
"unsigned": true,
"readOnly": true,
"allowManualEntry": false
},
{
"#": "3",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Lock Setpoint Changes"
},
{
"#": "4",
"label": "Thermostat Power Type",
"valueSize": 1,
"readOnly": true,
"allowManualEntry": false,
"options": [
{
"label": "C-Wire",
"value": 1
},
{
"label": "Batteries",
"value": 2
}
]
},
{
"#": "5",
"label": "Humidity Reporting Threshold",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "3 %rH",
"value": 1
},
{
"label": "5 %rH",
"value": 2
},
{
"label": "10 %rH",
"value": 3
}
]
},
{
"#": "6",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Auxiliary/Emergency Heating"
},
{
"#": "7",
"label": "Thermostat Hysteresis",
"description": "Variance allowed from setpoint to engage HVAC",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "0.5 °F",
"value": 1
},
{
"label": "1.0 °F",
"value": 2
},
{
"label": "1.5 °F",
"value": 3
},
{
"label": "2.0 °F",
"value": 4
},
{
"label": "2.5 °F",
"value": 5
},
{
"label": "3.0 °F",
"value": 6
},
{
"label": "3.5 °F",
"value": 7
},
{
"label": "4.0 °F",
"value": 8
}
]
},
{
"#": "8[0xff00]",
"label": "Heating Differential Temperature",
"valueSize": 2,
"defaultValue": 4,
"allowManualEntry": false,
"options": [
{
"label": "2.0 °F",
"value": 4
},
{
"label": "3.0 °F",
"value": 6
},
{
"label": "4.0 °F",
"value": 8
},
{
"label": "5.0 °F",
"value": 10
},
{
"label": "6.0 °F",
"value": 12
}
]
},
{
"#": "8[0xff]",
"label": "Cooling Differential Temperature",
"valueSize": 2,
"defaultValue": 4,
"allowManualEntry": false,
"options": [
{
"label": "2.0 °F",
"value": 4
},
{
"label": "3.0 °F",
"value": 6
},
{
"label": "4.0 °F",
"value": 8
},
{
"label": "5.0 °F",
"value": 10
},
{
"label": "6.0 °F",
"value": 12
}
]
},
{
"#": "9",
"label": "Thermostat Recovery Mode",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Fast",
"value": 1
},
{
"label": "Economy",
"value": 2
}
]
}
],
"compat": {
// https://github.com/zwave-js/node-zwave-js/issues/6017#issuecomment-1648532422
// The device has a weird endpoint setup. Most thermostat functionality is on endpoint 0, but the two additional
// endpoints have a thermostat device class:
// General Thermostat V2
// - "Manufacturer Specific"
// - "Thermostat Mode"
// - "Thermostat Setpoint"
// - "Version"
// plus the non-mandatory CCs
// - "Multilevel Sensor"
// - "Association"
// The additional endpoints simply mirror the root endpoint though, except the humidity sensor on endpoint 2.
// expose the application CCs on the root endpoint
"preserveRootApplicationCCValueIDs": true,
// Remove all Thermostat CCs from endpoints 1 and 2, as well as the sensor on endpoint 1
"commandClasses": {
"remove": {
"Basic": {
"endpoints": [1, 2]
},
"Thermostat Mode": {
"endpoints": [1, 2]
},
"Thermostat Setpoint": {
"endpoints": [1, 2]
},
"Multilevel Sensor": {
"endpoints": [1]
}
}
}
}
}