"manufacturer": "NorthQ",
"manufacturerId": "0x0096",
"label": "NQ-9022",
"description": "Electrical Meter",
"devices": [
{
"productType": "0x0001",
"productId": "0x0002"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Pulse Factor",
"description": "Impulse or Rotation factor per KWh * 10",
"valueSize": 4,
"minValue": 0,
"maxValue": 655350,
"defaultValue": 10000
},
{
"#": "2",
"label": "Sensor Type",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Pulse meter",
"value": 1
},
{
"label": "Mechanical meter",
"value": 2
}
]
},
{
"#": "3",
"label": "IR Listen Period",
"description": "Additional time for feedback measurement. Should always be 0.",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "4",
"label": "IR Pulse Width",
"description": "Adjusts transmit signal",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "5",
"label": "Poll / Wake Up Frequency",
"description": "Wake device up this many times per second.",
"valueSize": 1,
"minValue": 1,
"maxValue": 50,
"defaultValue": 20
},
{
"#": "6",
"label": "Pulse Threshold Low",
"description": "Low detection threshold for wheel meters",
"valueSize": 1,
"minValue": 0,
"maxValue": 143,
"defaultValue": 0,
"unsigned": true
},
{
"#": "7",
"label": "Pulse Threshold High",
"description": "High detection threshold for wheel meters",
"valueSize": 1,
"minValue": 0,
"maxValue": 143,
"defaultValue": 5,
"unsigned": true
},
{
"#": "8",
"label": "Wakeup Interval",
"description": "like WAKEUP command class",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0,
"unsigned": true
},
{
"#": "9",
"label": "Pulse Count",
"description": "Total pulse count (Meter reading / impulse factor)",
"valueSize": 4,
"minValue": 0,
"maxValue": 2147483647,
"defaultValue": 0
},
{
"#": "10",
"label": "Keep Alive Period",
"description": "How many seconds before going back to sleep in normal wakeup mode.",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 3,
"unsigned": true
},
{
"#": "11",
"label": "Real-Time Mode",
"description": "Set this to enter real-time mode from remote.",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0,
"unsigned": true
},
{
"#": "12",
"label": "Serial Number",
"description": "Read-only serial number in decimal",
"valueSize": 4,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0
},
{
"#": "13",
"label": "Debug Mode",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Off",
"value": 0
},
{
"label": "LED blinks at pulse counting",
"value": 1
}
]
},
{
"#": "15",
"label": "Calibration Status",
"description": "The calibration progress is calculated",
"valueSize": 4,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0
}
]
}