"manufacturer": "BeNext",
"manufacturerId": "0x008a",
"label": "Alarm Sound",
"description": "Alarm Sound",
"devices": [
{
"productType": "0x0005",
"productId": "0x0101"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Association group 1",
"description": "Changes the LED on the device",
"maxNodes": 1
},
"2": {
"label": "Association group 2",
"description": "The alarm sound reports it status to the associated devices",
"maxNodes": 1,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"label": "Set to Default",
"description": "Set all configuration values to default values (factory settings)",
"valueSize": 1,
"minValue": 1,
"maxValue": 255,
"defaultValue": 1,
"unsigned": true
},
{
"#": "2",
"label": "Destination Routine On/off",
"description": "Test connection by sending a periodic test with sound on failure",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 255,
"unsigned": true
},
{
"#": "3",
"label": "Desitnation Routine Success Time",
"description": "Time it takes to send a new frame after the last frame has successfully send",
"valueSize": 1,
"minValue": 0,
"maxValue": 60,
"defaultValue": 60
},
{
"#": "4",
"label": "Destination Routine Failed Time",
"description": "Time elapsed between failing to end a frame and sending a new frame.",
"valueSize": 1,
"minValue": 0,
"maxValue": 240,
"defaultValue": 240,
"unsigned": true
},
{
"#": "7",
"label": "Select Index Sound/light Mode",
"description": "The index of the sound mode when a Binary Switch/basic set frame been received",
"valueSize": 1,
"minValue": 0,
"maxValue": 6,
"defaultValue": 1
},
{
"#": "8",
"label": "Power Offline Sound/light Mode",
"description": "The sound and light mode that will be used when the device gets unplugged.",
"valueSize": 1,
"minValue": 0,
"maxValue": 6,
"defaultValue": 6
}
]
}