zwave-js/.config-db/devices/0x0059/ssp_301.json
2025-01-10 22:05:04 -08:00

51 lines
1.9 KiB
JSON

{
"manufacturer": "Secure Meters (UK) Ltd.",
"manufacturerId": "0x0059",
"label": "SSP 301",
"description": "SSP",
"devices": [
{
"productType": "0x000e",
"productId": "0x0001",
"zwaveAllianceId": [1174, 1253]
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Delta Based Switch Status Reporting",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 1,
"unsigned": true
},
{
"#": "2",
"label": "Time Interval Based Switch Status Reporting",
"valueSize": 2,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0
},
{
"#": "3",
"label": "LED Configuration",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
}
],
"metadata": {
"inclusion": "To include the SSP 301 onto a network, put the controller into inclusion mode. Now press and hold the button on SSP 301 for 4 to 7 seconds then\nrelease. The network status LED will start flashing (twice per second) on successful start of inclusion process. On successful inclusion the LED will turn off.",
"exclusion": "To exclude the SSP 301 from a network, put the controller into exclusion mode. Now press and hold the button on SSP 301 for 4 to 7 seconds then\nrelease. After successful exclusion the network status LED will start flashing once per second, and the device will reset to factory default.",
"reset": "Please use this procedure only when the primary controller is missing or otherwise inoperable, Power cycle the device, press and hold the button\nfor 7-11 seconds within the 60 seconds of power cycle to put the device in factory default. It reset all configuration and association to factory default. It also removes the device from Z-Wave network",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1174/SSP%20301%20resize%20for%20web%20final.pdf"
}
}