zwave-js/.config-db/devices/0x0039/39354_39461_zw4009.json
2025-01-10 22:05:04 -08:00

97 lines
2.8 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

{
"manufacturer": "Honeywell",
"manufacturerId": "0x0039",
"label": "39354 / 39461 / ZW4009",
"description": "In-Wall Toggle Switch, QFSW, 500S",
"devices": [
{
"productType": "0x4952",
"productId": "0x3137",
"zwaveAllianceId": 3400
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
},
"2": {
"label": "Local Load",
"maxNodes": 5
},
"3": {
"label": "Double Tap",
"maxNodes": 5,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "3",
"label": "LED Light",
"description": "LED status when device on or off.",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "LED on when load is off",
"value": 0
},
{
"label": "LED on when light is turned on",
"value": 1
},
{
"label": "LED always off",
"value": 2
},
{
"label": "LED always on",
"value": 3
}
]
},
{
"#": "4",
"label": "Invert Switch",
"description": "On/Off rocker settings can be reversed",
"valueSize": 1,
"minValue": 0,
"maxValue": 1,
"defaultValue": 0
},
{
"#": "19",
"label": "Alternate Exclusion",
"description": "Change the default exclusion behavior",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Press any button on the device",
"value": 0
},
{
"label": "Press 2 times on button and then 2 times off button, LED will flash 5 times if done successful",
"value": 1
}
]
}
],
"compat": {
"mapBasicSet": "event"
},
"metadata": {
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.\n2. Once the controller is ready to add your device, press up on the toggle.\n\nA. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the back of the box, or the QR code label on the product.\n\nNow you have complete control to turn your fixture ON/OFF according to groups, scenes, schedules and interactive automations programmed by your controller. If your Z-Wave certified controller features remote access, you can control your fixture from your mobile devices",
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press up on the toggle",
"reset": "Quickly press UP button 3 times, then, immediately press the DOWN button 3 times.\nNote: This should only be used in the event your networks primary controller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3400/39354-2.pdf"
}
}