156 lines
3.9 KiB
JSON
156 lines
3.9 KiB
JSON
{
|
||
"manufacturer": "Honeywell",
|
||
"manufacturerId": "0x0039",
|
||
"label": "39336 / 39443 / ZW3104",
|
||
"description": "Plug-In 1-Outlet Dimmer, 500S",
|
||
"devices": [
|
||
{
|
||
"productType": "0x5044",
|
||
"productId": "0x3038",
|
||
"zwaveAllianceId": [2681, 3743]
|
||
}
|
||
],
|
||
"firmwareVersion": {
|
||
"min": "0.0",
|
||
"max": "255.255"
|
||
},
|
||
"associations": {
|
||
"1": {
|
||
"label": "Lifeline",
|
||
"maxNodes": 5,
|
||
"isLifeline": true
|
||
},
|
||
"2": {
|
||
"label": "Local Load",
|
||
"maxNodes": 5
|
||
},
|
||
"3": {
|
||
"label": "Double Tap",
|
||
"maxNodes": 5,
|
||
"isLifeline": true
|
||
}
|
||
},
|
||
"paramInformation": [
|
||
{
|
||
"#": "3",
|
||
"label": "LED Light",
|
||
"description": "LED status when device on or off.",
|
||
"valueSize": 1,
|
||
"defaultValue": 0,
|
||
"allowManualEntry": false,
|
||
"options": [
|
||
{
|
||
"label": "LED on when load is off",
|
||
"value": 0
|
||
},
|
||
{
|
||
"label": "LED on when light is turned on",
|
||
"value": 1
|
||
},
|
||
{
|
||
"label": "LED always off",
|
||
"value": 2
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"#": "6",
|
||
"label": "Dim Up/down Rate",
|
||
"description": "Number of steps or levels",
|
||
"valueSize": 1,
|
||
"defaultValue": 0,
|
||
"allowManualEntry": false,
|
||
"options": [
|
||
{
|
||
"label": "Dim up/down quickly",
|
||
"value": 0
|
||
},
|
||
{
|
||
"label": "Dim up/down slowly",
|
||
"value": 1
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"#": "7",
|
||
"label": "Dim Rate Steps (Z-Wave Command)",
|
||
"description": "Number of steps or levels",
|
||
"valueSize": 1,
|
||
"minValue": 0,
|
||
"maxValue": 99,
|
||
"defaultValue": 1
|
||
},
|
||
{
|
||
"#": "8",
|
||
"label": "Dim Rate Timing (Z-Wave)",
|
||
"description": "Timing of steps or levels",
|
||
"valueSize": 2,
|
||
"unit": "10ms",
|
||
"minValue": 1,
|
||
"maxValue": 255,
|
||
"defaultValue": 3
|
||
},
|
||
{
|
||
"#": "9",
|
||
"label": "Dim Rate Steps (Manual)",
|
||
"description": "Number of steps or levels",
|
||
"valueSize": 1,
|
||
"minValue": 1,
|
||
"maxValue": 99,
|
||
"defaultValue": 1
|
||
},
|
||
{
|
||
"#": "10",
|
||
"label": "Dim Rate Timing (Manual)",
|
||
"description": "Timing of steps",
|
||
"valueSize": 2,
|
||
"unit": "10ms",
|
||
"minValue": 1,
|
||
"maxValue": 255,
|
||
"defaultValue": 3
|
||
},
|
||
{
|
||
"#": "11",
|
||
"label": "Dim Rate Steps (All-On/All-Off)",
|
||
"description": "Number of steps or levels",
|
||
"valueSize": 1,
|
||
"unit": "10ms",
|
||
"minValue": 1,
|
||
"maxValue": 99,
|
||
"defaultValue": 1
|
||
},
|
||
{
|
||
"#": "12",
|
||
"label": "Dim Rate Timing (All-On/All-Off)",
|
||
"description": "Timing of steps or levels",
|
||
"valueSize": 2,
|
||
"unit": "10ms",
|
||
"minValue": 1,
|
||
"maxValue": 255,
|
||
"defaultValue": 3
|
||
},
|
||
{
|
||
"#": "16",
|
||
"$import": "~/templates/master_template.json#base_enable_disable",
|
||
"label": "Switch Mode"
|
||
},
|
||
{
|
||
"#": "20",
|
||
"label": "Minimum Dim Level",
|
||
"description": "Number of Steps",
|
||
"valueSize": 1,
|
||
"minValue": 1,
|
||
"maxValue": 99,
|
||
"defaultValue": 1
|
||
}
|
||
],
|
||
"compat": {
|
||
"mapBasicSet": "event"
|
||
},
|
||
"metadata": {
|
||
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to add\nthe smart dimmer to the Z-Wave network.\n2. Once the controller is ready to add your smart dimmer, single\npress and release the manual/program button on the smart\ndimmer to add it in the network.\nPlease reference the controller/gateway’s manual for instructions",
|
||
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to\nremove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press and\nrelease the manual/program button on the smart dimmer to\nremove it from the network",
|
||
"reset": "To return your dimmer to factory defaults:\n1. If plugged in, unplug the device from the receptacle.\n2. Press and hold the top button, plug the device in, and continue to hold for at least 3 seconds.\nNote: This should only be used in the event your networks’ primary\ncontroller is missing or otherwise inoperable",
|
||
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3743/39443-HQSG_v3.pdf"
|
||
}
|
||
}
|