"manufacturer": "HomeSeer Technologies",
"manufacturerId": "0x000c",
"label": "HS-WX300",
"description": "Wall Dimmer & Switch",
"devices": [
{
"productType": "0x4447",
"productId": "0x4036",
"zwaveAllianceId": 4176
},
{
"productType": "0x4447",
"productId": "0x4037"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
},
"2": {
"label": "Group 2",
"maxNodes": 5
}
},
"paramInformation": [
{
"#": "3",
"$import": "templates/homeseer_template.json#led_indicator_inverted",
"label": "Bottom LED Operation"
},
{
"#": "4",
"$import": "~/templates/master_template.json#orientation"
},
{
"#": "5",
"$import": "templates/homeseer_template.json#dimming_threshold"
},
{
"#": "6",
"$import": "templates/homeseer_template.json#scene_control"
},
{
"#": "11",
"$import": "templates/homeseer_template.json#ramp_rate",
"label": "Ramp Rate (Z-Wave)"
},
{
"#": "12",
"$import": "templates/homeseer_template.json#ramp_rate",
"label": "Ramp Rate (Manual)"
},
{
"#": "13",
"$import": "templates/homeseer_template.json#status_mode",
"label": "Status Mode"
},
{
"#": "14",
"$import": "templates/homeseer_template.json#led_colors",
"label": "Load Status LED Color",
"description": "Set the LED color when displaying load status"
},
{
"#": "21",
"$import": "templates/homeseer_template.json#status_mode_choices",
"label": "Status LED 1 Color"
},
{
"#": "22",
"$import": "templates/homeseer_template.json#status_mode_choices",
"label": "Status LED 2 Color"
},
{
"#": "23",
"$import": "templates/homeseer_template.json#status_mode_choices",
"label": "Status LED 3 Color"
},
{
"#": "24",
"$import": "templates/homeseer_template.json#status_mode_choices",
"label": "Status LED 4 Color"
},
{
"#": "25",
"$import": "templates/homeseer_template.json#status_mode_choices",
"label": "Status LED 5 Color"
},
{
"#": "26",
"$import": "templates/homeseer_template.json#status_mode_choices",
"label": "Status LED 6 Color"
},
{
"#": "27",
"$import": "templates/homeseer_template.json#status_mode_choices",
"label": "Status LED 7 Color"
},
{
"#": "30",
"$import": "templates/homeseer_template.json#blink_frequency",
"label": "Custom Status Blink Frequency"
},
{
"#": "31[0x01]",
"$import": "templates/homeseer_template.json#led_blink_status",
"label": "LED 1 Blink Status"
},
{
"#": "31[0x02]",
"$import": "templates/homeseer_template.json#led_blink_status",
"label": "LED 2 Blink Status"
},
{
"#": "31[0x04]",
"$import": "templates/homeseer_template.json#led_blink_status",
"label": "LED 3 Blink Status"
},
{
"#": "31[0x08]",
"$import": "templates/homeseer_template.json#led_blink_status",
"label": "LED 4 Blink Status"
},
{
"#": "31[0x10]",
"$import": "templates/homeseer_template.json#led_blink_status",
"label": "LED 5 Blink Status"
},
{
"#": "31[0x20]",
"$import": "templates/homeseer_template.json#led_blink_status",
"label": "LED 6 Blink Status"
},
{
"#": "31[0x40]",
"$import": "templates/homeseer_template.json#led_blink_status",
"label": "LED 7 Blink Status"
},
{
"#": "32",
"label": "Wire Mode",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "3 wire mode (Neutral, line & load)",
"value": 0
},
{
"label": "2 wire mode (Line & load)",
"value": 1
}
]
},
{
"#": "33",
"$if": "firmwareVersion >= 1.13",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Indicate Operation Mode On Startup"
},
{
"#": "34",
"$if": "firmwareVersion >= 1.13",
"label": "Relative LED Indicator Brightness",
"valueSize": 1,
"minValue": 0,
"maxValue": 6,
"defaultValue": 3
},
{
"#": "35",
"$if": "firmwareVersion >= 1.13",
"label": "Paddle Behavior (Switch Mode)",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Top paddle turns on; Bottom paddle turns off",
"value": 0
},
{
"label": "Both paddles toggle",
"value": 1
}
]
},
{
"#": "36",
"$if": "firmwareVersion >= 1.13",
"label": "Default Brightness (Manual Control)",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 0,
"options": [
{
"label": "Last non-zero brightness",
"value": 0
}
]
},
{
"#": "37",
"$if": "firmwareVersion >= 1.13",
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
"label": "Control Load with Paddle",
"defaultValue": 0
}
],
"metadata": {
"inclusion": "1. Put your Z-Wave controller into inclusion (or exclusion) mode. Consult your controllers manual if youre unsure how to do this. \n2. In rapid succession, tap the bottom paddle 2 times, then press & hold the bottom paddle for 3 seconds (tap-tap-press & hold). This will initiate the inclusion (or exclusion) process. \nNote: The switch will default to dimmer mode after Z-Wave exclusion.",
"exclusion": "1. Put your Z-Wave controller into inclusion (or exclusion) mode. Consult your controllers manual if youre unsure how to do this. \n2. In rapid succession, tap the bottom paddle 2 times, then press & hold the bottom paddle for 3 seconds (tap-tap-press & hold). This will initiate the inclusion (or exclusion) process. \nNote: The switch will default to dimmer mode after Z-Wave exclusion.",
"reset": "To be used only in the event that the network primary controller is lost or otherwise inoperable.\n\n1. In rapid succession, tap the top paddle 3 times, then tap the bottom paddle 3 times. If all LEDs flash white 5 times, factory reset was successful. If not, repeat this procedure.\nNote: As this must be done very quickly, we recommend using 2 fingers for this operation; one on each paddle!\nNote: The switch will default to 3-wire mode and dimmer mode after factory reset",
"manual": "https://docs.homeseer.com/products/hs-wx300-r2-user-guide"
}
}