82 lines
2.9 KiB
JSON
82 lines
2.9 KiB
JSON
{
|
||
"manufacturer": "HomeSeer Technologies",
|
||
"manufacturerId": "0x000c",
|
||
"label": "HS-LS100+",
|
||
"description": "Z-Wave Plus Leak Sensor",
|
||
"devices": [
|
||
{
|
||
"productType": "0x0201",
|
||
"productId": "0x000a",
|
||
"zwaveAllianceId": 2735
|
||
}
|
||
],
|
||
"firmwareVersion": {
|
||
"min": "0.0",
|
||
"max": "255.255"
|
||
},
|
||
"paramInformation": [
|
||
{
|
||
"#": "14",
|
||
"$import": "templates/homeseer_template.json#enable_basic_set_command"
|
||
},
|
||
{
|
||
"#": "15",
|
||
"$import": "templates/homeseer_template.json#basic_set_value"
|
||
},
|
||
{
|
||
"#": "17",
|
||
"$import": "~/templates/master_template.json#base_0-255_nounit",
|
||
"label": "Flood Alarm Interval",
|
||
"unit": "minutes",
|
||
"defaultValue": 5
|
||
},
|
||
{
|
||
"#": "18",
|
||
"$import": "templates/homeseer_template.json#enable_shock_alarm"
|
||
},
|
||
{
|
||
"#": "19",
|
||
"label": "Temperature Report Interval",
|
||
"valueSize": 1,
|
||
"unit": "1/10 minutes",
|
||
"minValue": 3,
|
||
"maxValue": 240,
|
||
"defaultValue": 144,
|
||
"unsigned": true
|
||
},
|
||
{
|
||
"#": "20",
|
||
"label": "Temperature (High) Alarm Trigger Threshold",
|
||
"valueSize": 2,
|
||
"unit": "0.1 °F",
|
||
"minValue": -670,
|
||
"maxValue": 2570,
|
||
"defaultValue": 1040
|
||
},
|
||
{
|
||
"#": "22",
|
||
"label": "Temperature (Low) Trigger Threshold",
|
||
"valueSize": 2,
|
||
"unit": "0.1 °F",
|
||
"minValue": -670,
|
||
"maxValue": 2570,
|
||
"defaultValue": 320
|
||
},
|
||
{
|
||
"#": "24",
|
||
"$import": "~/templates/master_template.json#base_enable_disable",
|
||
"label": "Enable / Disable Blinking LED",
|
||
"defaultValue": 1
|
||
},
|
||
{
|
||
"#": "32",
|
||
"$import": "templates/homeseer_template.json#low_battery_level"
|
||
}
|
||
],
|
||
"metadata": {
|
||
"inclusion": "1) Open the cover.\n2) Place the device within the direct range of your Z-Wave controller.\n3) Set the main controller in add mode (see the controller’s manual).\n4) Click the Z-button once (non-secure inclusion) or triple click (secure inclusion) the Z-button quickly, the LED indicator should blink fast. \n5) Wait for the adding process to end.\n6) Successful adding will be confirmed by the Z-Wave controller’s message.",
|
||
"exclusion": "1) Open the cover.\n2) Place the device within the direct range of your Z-Wave controller.\n3) Set the main controller remove mode (see the controller’s manual).\n4) Triple click the Z-button quickly, the LED indicator should blink fast.\n5) Wait for the removing process to end.\n6) Successful adding will be confirmed by the Z-Wave controller’s message.",
|
||
"reset": "1) Power on the device\n2) Press and hold the Z button for more than 20 seconds,\n3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete.\n4) The reset feature works only when the device has been included into a Z-Wave network.\n\nUse this procedure only in the event that the network primary controller is missing or otherwise inoperable.",
|
||