121 lines
3 KiB
JSON
121 lines
3 KiB
JSON
{
|
|
"manufacturer": "Q-light",
|
|
"manufacturerId": "0x0433",
|
|
"label": "ZERODIM 2-Pol",
|
|
"description": "Q-Light Zerodim 2-Pol",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0003",
|
|
"productId": "0x000e"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"associations": {
|
|
"1": {
|
|
"label": "Lifeline",
|
|
"maxNodes": 1,
|
|
"isLifeline": true
|
|
},
|
|
"2": {
|
|
"label": "On/Off (rotary knob) - Basic command", // Mirror of endpoint 1, group 2,
|
|
"maxNodes": 5
|
|
},
|
|
"3": {
|
|
"label": "Dimmer (rotary knob) - Multilevel switch command", // Mirror of endpoint 1, group 3,
|
|
"maxNodes": 5
|
|
}
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Minimum Brightness Level",
|
|
"description": "Set the desired value from 1 to 98% for the minimum dim level that the dimmer is restricted to, the dimmer will not go lower than the value set here.",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 1,
|
|
"maxValue": 98,
|
|
"defaultValue": 10
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "Maximum Brightness Level",
|
|
"description": "Set the desired value from 2 to 99% for the maximum dim level that the dimmer is restricted to; the dimmer will not go higher than the value set here.",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 2,
|
|
"maxValue": 99,
|
|
"defaultValue": 99
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Automatic Control - Dimming Step Size",
|
|
"description": "This parameter defines the percentage value of dimming step during the automatic control.",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 1,
|
|
"maxValue": 99,
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Automatic Control - Time of A Dimming Step",
|
|
"description": "This parameter defines the time of single dimming step set in parameter 3 during the automatic control.",
|
|
"valueSize": 1,
|
|
"minValue": 1,
|
|
"maxValue": 255,
|
|
"defaultValue": 1,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "Manual Control - Dimming Step Size",
|
|
"description": "This parameter defines the percentage value of dimming step during the manual control.",
|
|
"valueSize": 1,
|
|
"minValue": 1,
|
|
"maxValue": 99,
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Manual Control - Time of A Dimming Step",
|
|
"description": "This parameter defines the time of single dimming step setin parameter 5 during the manual control.",
|
|
"valueSize": 1,
|
|
"minValue": 1,
|
|
"maxValue": 255,
|
|
"defaultValue": 5,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "7",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev"
|
|
},
|
|
{
|
|
"#": "8",
|
|
"label": "Scene ID Set",
|
|
"description": "Scene ID is set by this configuration. Note: The actual action of each SCENE ID are set by SCENE_ACTUATOR_CONF(0x26) command.",
|
|
"valueSize": 1,
|
|
"minValue": 1,
|
|
"maxValue": 255,
|
|
"defaultValue": 1,
|
|
"unsigned": true
|
|
},
|
|
{
|
|
"#": "9",
|
|
"label": "Auto-Off Timer",
|
|
"valueSize": 2,
|
|
"unit": "seconds",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|