"manufacturer": "Sunricher",
|
|
"manufacturerId": "0x0330",
|
|
"label": "ZV9080A-A",
|
|
"description": "Curtain Motor Controller",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0200",
|
|
"productId": "0xd00d",
|
|
"zwaveAllianceId": 3342
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"associations": {
|
|
"1": {
|
|
"label": "Lifeline",
|
|
"maxNodes": 5,
|
|
"isLifeline": true
|
|
},
|
|
"2": {
|
|
"label": "Endpoint 1: Multilevel Switch Reports",
|
|
"maxNodes": 5
|
|
},
|
|
"3": {
|
|
"label": "Endpoint 2: Binary Switch Reports",
|
|
"maxNodes": 5
|
|
}
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "2",
|
|
"label": "Intermediate Reports",
|
|
"valueSize": 1,
|
|
"unit": "%",
|
|
"minValue": 0,
|
|
"maxValue": 10,
|
|
"defaultValue": 1,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Working Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 2,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Light mode",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Shutter mode without positioning",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Shutter mode with positioning",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Venetian mode (Up/Down and slats rotation)",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"$import": "~/templates/master_template.json#base_enable_disable",
|
|
"label": "Remember Last State",
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"#": "5",
|
|
"$import": "~/templates/master_template.json#base_enable_disable",
|
|
"label": "Overcurrent Protection",
|
|
"defaultValue": 1
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Calibration",
|
|
"description": "Venetian mode only",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Not calibrated",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Calibrated / Start calibration",
|
|
"value": 1
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "7",
|
|
"label": "Switch Configuration",
|
|
"description": "Light mode only",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Short press S1: Toggle Q1. Hold down S1: Switch Q1 on. Release S1: Switch Q2 off. Short press S2: Toggle Q2. Hold down S2: Switch Q2 on. Release S2: Switch Q1 off",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Short press S1: Toggle Q1. Short press S2: Toggle Q2",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Hold down S1: Switch Q1 on. Release S1: Switch Q2 off. Hold down S2: Switch Q2 on. Release S2: Switch Q1 off",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Short press S1 or S2: Toggle Q1/Q2",
|
|
"value": 3
|
|
},
|
|
{
|
|
"label": "Hold down S1: Switch Q1/Q2 on. Hold down S2: Switch Q1/Q2 off",
|
|
"value": 4
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "8",
|
|
"$import": "~/templates/master_template.json#base_enable_disable_inverted",
|
|
"label": "Inclusion/Exclusion Using Switch S1"
|
|
},
|
|
{
|
|
"#": "9",
|
|
"label": "Send Central Scene Notifications",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable both switches",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Enable S1 only",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Enable S2 only",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "10",
|
|
"label": "Power Change Report Threshold",
|
|
"valueSize": 1,
|
|
"unit": "W",
|
|
"minValue": 0,
|
|
"maxValue": 100,
|
|
"defaultValue": 10,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "11",
|
|
"label": "Current Change Report Threshold",
|
|
"valueSize": 1,
|
|
"unit": "0.1 A",
|
|
"minValue": 0,
|
|
"maxValue": 10,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "12",
|
|
"label": "Voltage Change Report Threshold",
|
|
"valueSize": 1,
|
|
"unit": "V",
|
|
"minValue": 0,
|
|
"maxValue": 10,
|
|
"defaultValue": 0,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "13",
|
|
"label": "Slats Rotation Time",
|
|
"description": "Venetian mode only. Allowable range: 5-250 (0.5-25s)",
|
|
"valueSize": 1,
|
|
"unit": "0.1s",
|
|
"minValue": 0,
|
|
"maxValue": 250,
|
|
"defaultValue": 15,
|
|
"unsigned": true,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "14",
|
|
"label": "Energy Report Interval",
|
|
"valueSize": 4,
|
|
"unit": "seconds",
|
|
"minValue": 60,
|
|
"maxValue": 2678400,
|
|
"defaultValue": 3600
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "Press button K2 on the unit 3 times, or when S1 is enabled press the switch 3 times",
|
|
"exclusion": "Press button K2 on the unit 3 times, or when S1 is enabled press the switch 3 times",
|
|
"reset": "Find the button k2 on the unit and hold for over 10s",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3342/SR-ZV9080A-AZ-WaveCurtainMotorController_1.pdf"
|
|
}
|
|
}
|