"manufacturer": "Anchor Tech",
|
|
"manufacturerId": "0x032b",
|
|
"label": "ZD2102-5",
|
|
"description": "Door Sensor",
|
|
"devices": [
|
|
{
|
|
"productType": "0x2001",
|
|
"productId": "0x0106",
|
|
"zwaveAllianceId": [2249, 2250]
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Configuration - External Switch",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"unsigned": true,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Disable",
|
|
"value": 0
|
|
},
|
|
{
|
|
"label": "Enable",
|
|
"value": 255
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "For “Inclusion” (adding to) a network: Put the Z-Wave™ network controller into “inclusion” mode following its instructions. To add the ZD2102-5 to your controller press the program switch of ZD2102-5 to send the Node Information Frame (NIF). After sending NIF, the network controller will send the auto inclusion request; otherwise, ZD2102-5 will go to sleep after 15 seconds",
|
|
"exclusion": "For “Exclusion” (removing from) a network: Put the Z-Wave™ network controller into “exclusion” mode, following its instructions. To delete the ZD2102-5 from your controller press the program switch of ZD2102-5 for at least 1 second to be excluded. Note: All user and network settings will be cleared and the device reset to factory setting defaults when the device is excluded",
|
|
"reset": "Factory Default Reset: Trigger the rear cover switch to send the Alarm Report and trigger the reed switch (close & open) 5 times in 10 seconds, ZD2102-5 will send the “Device Reset Locally Notification” command and reset to the factory default condition. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2249/ZD%202102_10252013.pdf"
|
|
}
|
|
}
|