"manufacturer": "Vemmio",
|
|
"manufacturerId": "0x030f",
|
|
"label": "DS100",
|
|
"description": "Double Switch in A Dual Relay In-Wall Module.",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0001",
|
|
"productId": "0x0001"
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "0",
|
|
"label": "Watt Meter Report Period",
|
|
"description": "720*5s=3600s=1hour",
|
|
"valueSize": 2,
|
|
"unit": "5s",
|
|
"minValue": 1,
|
|
"maxValue": 32767,
|
|
"defaultValue": 720
|
|
},
|
|
{
|
|
"#": "2",
|
|
"label": "KWH Meter Report Period",
|
|
"description": "6*10 min = 1 hour",
|
|
"valueSize": 2,
|
|
"unit": "10 minutes",
|
|
"minValue": 1,
|
|
"maxValue": 32767,
|
|
"defaultValue": 6
|
|
},
|
|
{
|
|
"#": "3",
|
|
"label": "Selected Relay",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Relay 1",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Relay 2",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Relay 1 & 2",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "4",
|
|
"label": "Edge or Pulse Mode or Edge-Toggle Mode",
|
|
"valueSize": 1,
|
|
"defaultValue": 1,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Edge mode",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Pulse mode",
|
|
"value": 2
|
|
},
|
|
{
|
|
"label": "Edge-Toggle mode",
|
|
"value": 3
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"#": "5",
|
|
"label": "Threshold of Current for Load Caution",
|
|
"description": "750*0.01A=7.5A",
|
|
"valueSize": 2,
|
|
"unit": "0.01A",
|
|
"minValue": 10,
|
|
"maxValue": 750,
|
|
"defaultValue": 750
|
|
},
|
|
{
|
|
"#": "6",
|
|
"label": "Threshold of kWh for Load Caution",
|
|
"valueSize": 2,
|
|
"unit": "1KWh",
|
|
"minValue": 1,
|
|
"maxValue": 10000,
|
|
"defaultValue": 10000
|
|
},
|
|
{
|
|
"#": "7",
|
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on"
|
|
},
|
|
{
|
|
"#": "8",
|
|
"label": "Auto Off Timer",
|
|
"description": "0: Disable auto off function, 1: 0x0-0x7FFF 1s-32767s",
|
|
"valueSize": 2,
|
|
"unit": "1s",
|
|
"minValue": 0,
|
|
"maxValue": 32767,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "9",
|
|
"label": "RF Off Command Mode",
|
|
"description": "0: Switch off, 1: Ignore, 2: Switch toggle, 3: Switch on",
|
|
"valueSize": 1,
|
|
"minValue": 0,
|
|
"maxValue": 3,
|
|
"defaultValue": 0
|
|
},
|
|
{
|
|
"#": "10",
|
|
"label": "Existence of Endpoint 3",
|
|
"description": "1: endpoint 3 exists, 2: No endpoint 3",
|
|
"valueSize": 1,
|
|
"minValue": 1,
|
|
"maxValue": 2,
|
|
"defaultValue": 1
|
|
}
|
|
]
|
|
}
|