"manufacturer": "AMADAS Co., Ltd.",
|
|
"manufacturerId": "0x029f",
|
|
"label": "ADSL-1001",
|
|
"description": "AMADAS Smart Lock",
|
|
"devices": [
|
|
{
|
|
"productType": "0x0003",
|
|
"productId": "0x0001",
|
|
"zwaveAllianceId": [2436, 2846]
|
|
}
|
|
],
|
|
"firmwareVersion": {
|
|
"min": "0.0",
|
|
"max": "255.255"
|
|
},
|
|
"paramInformation": [
|
|
{
|
|
"#": "1",
|
|
"label": "Set Door Open Notification On or Off",
|
|
"valueSize": 1,
|
|
"defaultValue": 0,
|
|
"unsigned": true,
|
|
"allowManualEntry": false,
|
|
"options": [
|
|
{
|
|
"label": "Set door open notification on",
|
|
"value": 1
|
|
},
|
|
{
|
|
"label": "Set door open notification off",
|
|
"value": 254
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metadata": {
|
|
"inclusion": "- Z-Wave inclusion:\n\ni. Press “Z-Wave Settings” button in the inner side for 3 seconds. (toggle status) \n\nii. Then “Blue LED” will turn on.\n\niii. When the inclusion is complete, the led is turned off and the beep sounds. Please wait.\n\n* Beep : Success (Beep), Fail (Beep~)\n* The inclusion results can be found in the controller or in your app",
|
|
"exclusion": "- Z-Wave exclusion \n\ni. Press “Z-Wave Settings” button in the inner side for 3 seconds. (toggle status)\n\nii. Then “Blue LED” will turn on.\n\niii. When the exclusion is completed, the led is turned off and the beep sounds. Please wait.\n\n* Beep : Success (Beep Beep), Fail (Beep~)\n* The exclusion results can be found in the controller or in your app",
|
|
"reset": "1. Factory default setting \n\ni. Press “Settings, Input” button in the inner side for 3 seconds.\n\nii. Press “④ - Reset” button in the outer side.\n\niii. Enter “1004” and press the “*” button.\n\n2. Z-Wave device reset locally \n\ni. Press “Z-Wave Settings” button in the inner side 3 times within 1.5 seconds.\n\nii. Then “White LED” will turn on.\n\niii. When the “network reset locally” is complete, the led is turned off. Please wait.\n\n* Beep : Success (Ring), Fail (Beep~)\n* Z-Wave network information is initialized.\n* Please use this procedure only when the network primary controller is missing or otherwise inoperable",
|
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2436/User%20and%20Reference%20Guide.pdf"
|
|
}
|
|
}
|