"manufacturer": "Shenzhen Kaadas Intelligent Technology Co., Ltd.",
"manufacturerId": "0x021d",
"label": "DB2",
"description": "Touchscreen Digital Deadbolt",
"devices": [
{
"productType": "0x0003",
"productId": "0x0001",
"zwaveAllianceId": 3324
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"metadata": {
"inclusion": "-Follow the user guide of hub to enter inclusion mode.\n-Operate on lock following guide below:\n1.Enter master mode(refer to programming instruction)\n2.Input “8” to enter “function extension settings”\n3.Input “1” to join a network",
"exclusion": "-Follow the user guide of hub to enter exclusion mode.\n-Operate on lock following guide below:\n1.Enter master mode(refer to programming instruction)\n2.Input “8” to enter “function extension settings”\n3.Input “2” to log off a network",
"reset": "※Please use this procedure only when the network primary controller is missing or inoperable.\n-Operations on lock\n1.Open the door and keep the lock in \"unlock\" status\n2.Open battery box and find the reset button. \n3.Use a sharp thing to press and hold the reset button.\n4.Keep holding the reset button and remove a battery from battery box then replace it.\n5.Keep holding the reset button until hearing voice guide",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3324/Alfred%20Z-Wave%20Plus%20System%20Integrators%20Guide%20V5.1.pdf"
}
}