zwave-js/.config-db/devices/0x0148/spirit.json
2025-01-10 22:05:04 -08:00

164 lines
2.9 KiB
JSON

{
"manufacturer": "Eurotronics",
"manufacturerId": "0x0148",
"label": "Spirit",
"description": "Thermostatic Valve",
"devices": [
{
"productType": "0x0003",
"productId": "0x0001"
},
{
"productType": "0x0003",
"productId": "0x0003"
},
{
"productType": "0x0003",
"productId": "0x0004"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Invert LCD",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Normal",
"value": 0
},
{
"label": "Inverted (UK edition)",
"value": 1
}
]
},
{
"#": "2",
"label": "LCD Timeout",
"valueSize": 1,
"unit": "seconds",
"minValue": 0,
"maxValue": 30,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "3",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Backlight",
"defaultValue": 1
},
{
"#": "4",
"label": "Battery Report",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "System notification",
"value": 0
},
{
"label": "Send battery status unsolicited once a day",
"value": 1
}
]
},
{
"#": "5",
"label": "Temperature Report Threshold",
"valueSize": 1,
"unit": "0.1 °C",
"minValue": 0,
"maxValue": 50,
"defaultValue": 5
},
{
"#": "6",
"label": "Valve Opening Percentage Report",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 100,
"defaultValue": 0
},
{
"#": "7",
"label": "Window Open Detection",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "Sensitivity low",
"value": 1
},
{
"label": "Sensitivity medium",
"value": 2
},
{
"label": "Sensitivity high",
"value": 3
}
]
},
{
"#": "8",
"label": "Temperature Offset",
"valueSize": 1,
"unit": "0.1 °C",
"minValue": -128,
"maxValue": 50,
"defaultValue": 0,
"options": [
{
"label": "Ext temp sensor be used for regul",
"value": -128
}
]
}
],
"compat": {
"overrideQueries": {
// The device does not report "Manufacturer specific" as a supported thermostat mode
"Thermostat Mode": [
{
"method": "getSupportedModes",
"result": [0, 1, 11, 15, 31], // Off / Heat / Energy heat / Full power / Manufacturer specific
"persistValues": {
"supportedModes": [0, 1, 11, 15, 31]
},
"extendMetadata": {
"thermostatMode": {
"states": {
"0": "Off",
"1": "Heat",
"11": "Energy heat",
"15": "Full power",
"31": "Manufacturer specific"
}
}
}
}
]
}
}
}