{ "manufacturer": "Aeotec Ltd.", "manufacturerId": "0x0371", "label": "ZWA023", "description": "Smart Switch 7", "devices": [ { "productType": "0x0103", "productId": "0x0017", "zwaveAllianceId": 3844 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 5, "isLifeline": true }, "2": { "label": "Retransmit", "maxNodes": 5 }, "3": { "label": "Alert", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "$import": "~/0x0086/templates/aeotec_template.json#led_indicator_three_options_alt" }, { "#": "2", "label": "Night Light: On Time", "description": "Set in hex format: 0xHHMMSS", "valueSize": 4, "minValue": 0, "maxValue": 2316633, "defaultValue": 1572864 }, { "#": "3", "label": "Night Light: Off Time", "description": "Set in hex format: 0xHHMMSS", "valueSize": 4, "minValue": 0, "maxValue": 2316633, "defaultValue": 393216 }, { "#": "4", "$import": "~/0x0086/templates/aeotec_template.json#blink_duration" }, { "#": "5", "label": "LED Blink Speed", "description": "Number of blinks per second", "valueSize": 1, "minValue": 1, "maxValue": 24, "defaultValue": 5 }, { "#": "6", "label": "Power Report Threshold (Scene)", "description": "Power consumption at which to send a scene activation set command", "valueSize": 2, "unit": "W", "minValue": 0, "maxValue": 3000, "defaultValue": 100, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "7", "label": "Local Control", "valueSize": 1, "minValue": 0, "maxValue": 2, "defaultValue": 0, "options": [ { "label": "Normal operation", "value": 0 }, { "label": "Z-Wave control only", "value": 1 }, { "label": "Always on", "value": 2 } ] }, { "#": "8", "$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off" }, { "#": "9", "label": "Scene Id (Group 3)", "description": "Set the scene id when scene activation set command is sent", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "10", "$import": "~/0x0086/templates/aeotec_template.json#current_overload_threshold", "maxValue": 1800, "defaultValue": 1800 }, { "#": "11", "label": "Voltage Overload Protection", "description": "Allowable range: 95-255", "valueSize": 1, "unit": "V", "minValue": 0, "maxValue": 255, "defaultValue": 135, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "19", "label": "Threshold Check Interval", "description": "Defines the frequency at which the automatic reporting thresholds are evaluated", "valueSize": 1, "unit": "seconds", "minValue": 0, "maxValue": 255, "defaultValue": 5, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "20", "$import": "~/0x0086/templates/aeotec_template.json#kwh_threshold" }, { "#": "21", "$import": "~/0x0086/templates/aeotec_template.json#power_threshold", "maxValue": 2500, "defaultValue": 0 }, { "#": "22", "$import": "~/0x0086/templates/aeotec_template.json#current_threshold" }, { "#": "23", "$import": "~/0x0086/templates/aeotec_template.json#auto_report_interval_watt", "valueSize": 2 }, { "#": "24", "$import": "~/0x0086/templates/aeotec_template.json#auto_report_interval_kwh", "valueSize": 2 }, { "#": "25", "$import": "~/0x0086/templates/aeotec_template.json#auto_report_interval_v", "valueSize": 2 }, { "#": "26", "$import": "~/0x0086/templates/aeotec_template.json#auto_report_interval_amp", "valueSize": 2 }, { "#": "30[0x01]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "React to Alarm Type: Smoke" }, { "#": "30[0x02]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "React to Alarm Type: CO" }, { "#": "30[0x04]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "React to Alarm Type: CO2" }, { "#": "30[0x08]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "React to Alarm Type: Heat" }, { "#": "30[0x10]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "React to Alarm Type: Water" }, { "#": "30[0x20]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "React to Alarm Type: Access Control" }, { "#": "30[0x40]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "React to Alarm Type: Home Security (Intrusion)" }, { "#": "30[0x80]", "$import": "~/templates/master_template.json#base_enable_disable", "label": "React to Alarm Type: Home Security (Motion)" }, { "#": "31", "label": "Alarm Response", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true, "options": [ { "label": "Disable", "value": 0 }, { "label": "On", "value": 1 }, { "label": "Off", "value": 2 } ] }, { "#": "32", "label": "Alarm Disable Setting", "description": "Allowable range: 5-255", "valueSize": 1, "unit": "seconds", "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true, "options": [ { "label": "Tap action button once", "value": 0 }, { "label": "Tap action button twice", "value": 1 }, { "label": "Tap action button four times", "value": 2 }, { "label": "Press and hold action button for four seconds", "value": 4 } ] }, { "#": "40", "$import": "~/0x0086/templates/aeotec_template.json#auto_off_timer" }, { "#": "41", "$import": "~/0x0086/templates/aeotec_template.json#auto_on_timer" }, { "#": "42", "$import": "~/0x0086/templates/aeotec_template.json#binary_report_type" } ], "metadata": { "inclusion": "Turn the gateway/ primary controller into inclusion mode, then short press the Action Button on the product one time.", "exclusion": "Turn the gateway/ primary controller into exclusion mode, then short press the Action Button on the product 2 times.", "reset": "Press and hold the Action Button for 15-20s.\n\nNote: Please use this procedure only when the network primary controller is missing or otherwise inoperable", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3844/User%20manual%20-%20Smart%20Switch%207%20_US-2.pdf" } }