{ "manufacturer": "Aeotec Ltd.", "manufacturerId": "0x0371", "label": "ZWA009", // eslint-disable-next-line @zwave-js/consistent-config-string-case "description": "aërQ Temperature and Humidity Sensor V1.0", "devices": [ { "productType": "0x0002", "productId": "0x0009" }, { "productType": "0x0102", "productId": "0x0009" }, { "productType": "0x0202", "productId": "0x0009" } ], "firmwareVersion": { "min": "0.0", "max": "1.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 5, "isLifeline": true }, "2": { "label": "High Temperature", "maxNodes": 5 }, "3": { "label": "Low Temperature", "maxNodes": 5 }, "4": { "label": "High Humidity", "maxNodes": 5 }, "5": { "label": "Low Humidity", "maxNodes": 5 }, "6": { "label": "Air Temperature (Multilevel)", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "label": "Temperature Change Report Threshold", "valueSize": 1, "unit": "0.1 °(C/F)", "minValue": 0, "maxValue": 100, "defaultValue": 20, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "2", "label": "Humidity Change Report Threshold", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 20, "defaultValue": 5, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "4", "label": "Automatic Reporting Interval", "description": "Allowable Range: 900-65535", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 65535, "defaultValue": 43200, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "5", "label": "High Temperature Basic Set Threshold", "valueSize": 2, "unit": "0.1 °(C/F)", "minValue": 0, "maxValue": 1000, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "10", "label": "High Temperature Basic Set Value", "description": "Allowable Range: 0-99, 255.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "6", "label": "Low Temperature Basic Set Threshold", "description": "Allowable Range: 200-1000.", "valueSize": 2, "unit": "0.1 °(C/F)", "minValue": 0, "maxValue": 1000, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "9", "label": "Low Temperature Basic Set Value", "description": "Allowable Range: 0-99, 255.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "7", "label": "High Humidity Basic Set Threshold", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 90, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "12", "label": "High Humidity Trigger Basic Set Value", "description": "Allowable Range: 0-99, 255.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "8", "label": "Low Humidity Basic Set Threshold", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 90, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "11", "label": "Low Humidity Trigger Basic Set Value", "description": "Allowable Range: 0-99, 255.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "13", "label": "Humidity Offset for Mold Danger Notification", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 10, "defaultValue": 0 }, { "#": "64", "$import": "~/0x0086/templates/aeotec_template.json#celsius_fahrenheit", "valueSize": 1 }, { "#": "255", "$import": "~/0x0086/templates/aeotec_template.json#factory_reset_complete" } ] }