{ "manufacturer": "Vesternet", "manufacturerId": "0x0330", "label": "VES-ZW-SWI-014", "description": "2 Channel Switch", "devices": [ { "productType": "0x0004", "productId": "0xd109" } ], "firmwareVersion": { "min": "1.2.5", "max": "1.3.6" }, "paramInformation": [ { "#": "2", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Binary Report on State Change", "defaultValue": 1 }, { "#": "4", "$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev" }, { "#": "5", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Over Current Protection", "description": "Triggered when module goes over current limit.", "defaultValue": 1 }, { "#": "7", "label": "Momentary Switch Input Behaviour", "description": "Only valid in Light Mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "All the same, toggle the respective output", "value": 0 }, { "label": "Short press only, toggle the respective output", "value": 1 }, { "label": "Hold & release only, toggle the respective output", "value": 2 }, { "label": "Short press only, toggle both outputs", "value": 3 }, { "label": "Hold & release only, toggle both outputs", "value": 4 } ] }, { "#": "8", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Inclusion / Exclusion Using External Switch On Input S1", "defaultValue": 1 }, { "#": "9", "label": "Send Central Scene Commands in Response to Inputs", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disabled for both inputs", "value": 0 }, { "label": "Enabled for both inputs", "value": 1 }, { "label": "Enable for S1 input only", "value": 2 }, { "label": "Enable for S2 input only", "value": 3 } ] }, { "#": "10", "label": "Power Change Report Threshold", "valueSize": 1, "unit": "W", "minValue": 0, "maxValue": 100, "defaultValue": 10, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "11", "label": "Current Change Report Threshold", "valueSize": 1, "unit": "0.1 A", "minValue": 0, "maxValue": 10, "defaultValue": 1, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "12", "label": "Voltage Change Report Threshold", "valueSize": 1, "unit": "V", "minValue": 0, "maxValue": 10, "defaultValue": 2, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "14", "label": "Energy/Power/Voltage/Current Report Interval", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 3600, "options": [ { "label": "Disable", "value": 0 } ] } ], "metadata": { "inclusion": "Step 1. Set primary controller/gateway into inclusion mode.\nStep 2. Either power cycle the product, or triple press the action button.\n Step 3. The connected light will stay on solid for 3 seconds to indicate successful inclusion.", "exclusion": "Step 1. Set primary controller/gateway into exclusion mode.\nStep 2. Triple press the action button.", "reset": "Press and hold the action button for over 10 seconds.", "manual": "https://cdn.shopify.com/s/files/1/0066/8149/3559/files/VES-ZW-SWI-014.pdf" } }