{ "manufacturer": "Vesternet", "manufacturerId": "0x0330", "label": "VES-ZW-HLD-016", "description": "High Load Switch", "devices": [ { "productType": "0x0004", "productId": "0xd019" } ], "firmwareVersion": { "min": "2.2.5", "max": "2.4.6" }, "paramInformation": [ { "#": "2", "$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev" }, { "#": "3", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Basic Report on State Change", "defaultValue": 1 }, { "#": "4", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Over Current Protection", "description": "Triggered at over 16A.", "defaultValue": 1 }, { "#": "5", "label": "Switch Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Momentary", "value": 0 }, { "label": "Toggle", "value": 1 } ] }, { "#": "10", "label": "Power Change Report Threshold", "valueSize": 1, "unit": "W", "minValue": 0, "maxValue": 255, "defaultValue": 5, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "11", "label": "Current Change Report Threshold", "valueSize": 1, "unit": "0.1 A", "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "12", "label": "Voltage Change Report Threshold", "valueSize": 1, "unit": "V", "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "13", "label": "Energy/Power/Voltage/Current Report Interval", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 1800, "options": [ { "label": "Disable", "value": 0 } ] } ], "metadata": { "inclusion": "Step 1. Set primary controller/gateway into inclusion mode.\nStep 2. Either power cycle the product, or triple press the action button.\n Step 3. The connected light will stay on solid for 3 seconds to indicate successful inclusion.", "exclusion": "Step 1. Set primary controller/gateway into exclusion mode.\nStep 2. Triple press the action button.", "reset": "Press and hold the action button for over 10 seconds. The connected light will be set to 50% brightness and flash slowly.", "manual": "https://cdn.shopify.com/s/files/1/0066/8149/3559/files/VES-ZW-HLD-016.pdf" } }