{ "manufacturer": "Minoston", "manufacturerId": "0x0312", "label": "MSE30Z", "description": "Door/Window Temperature & Humidity Sensor", "devices": [ { "productType": "0x0713", "productId": "0xd100", "zwaveAllianceId": 4193 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 3, "isLifeline": true }, "2": { "label": "Door State", "maxNodes": 5 }, "3": { "label": "High Temperature", "maxNodes": 5 }, "4": { "label": "Low Temperature", "maxNodes": 5 }, "5": { "label": "High Humidity", "maxNodes": 5 }, "6": { "label": "Low Humidity", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "label": "Battery Reporting Threshold", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 20, "defaultValue": 10 }, { "#": "2", "label": "Low Battery Alarm Threshold", "valueSize": 1, "unit": "%", "minValue": 5, "maxValue": 20, "defaultValue": 5 }, { "#": "3", "label": "Invert Sensor", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Closed when magnet is near", "value": 0 }, { "label": "Opened when magnet is near", "value": 1 } ] }, { "#": "4", "label": "Door Close Command Delay", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 3600, "defaultValue": 0 }, { "#": "5", "label": "Door Open Command Delay", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 3600, "defaultValue": 0 }, { "#": "6", "label": "Automatic Reporting: Temperature Change Threshold", "valueSize": 1, "unit": "0.5 °C", "minValue": 1, "maxValue": 9, "defaultValue": 3 }, { "#": "7", "label": "Automatic Reporting: Humidity Change Threshold", "valueSize": 1, "unit": "%", "minValue": 5, "maxValue": 20, "defaultValue": 10 }, { "#": "8", "label": "Automatic Reporting: High Temperature Limit", "valueSize": 1, "unit": "°C", "minValue": 0, "maxValue": 50, "defaultValue": 0 }, { "#": "9", "label": "Automatic Reporting: Low Temperature Limit", "valueSize": 1, "unit": "°C", "minValue": 0, "maxValue": 50, "defaultValue": 0 }, { "#": "10", "label": "Automatic Reporting: High Humidity Limit", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 0 }, { "#": "11", "label": "Automatic Reporting: Low Humidity Limit", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 0 }, { "#": "12", "$import": "~/templates/master_template.json#temperature_scale_celsius_fahrenheit" }, { "#": "13", "label": "Association Group 2 Function", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Send Basic Set 0xff when magnet is away; 0x00 when near", "value": 1 }, { "label": "Send Basic Set 0x00 when magnet is away; 0xff when near", "value": 2 }, { "label": "Only send Basic Set 0xff when magnet is away", "value": 3 }, { "label": "Only send Basic Set 0x00 when magnet is near", "value": 4 }, { "label": "Only send Basic Set 0x00 when magnet is away", "value": 5 }, { "label": "Only send Basic Set 0xff when magnet is near", "value": 6 } ] } ], "metadata": { "inclusion": "1. Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.\n2. When prompted by your primary controller, click the button three times in one second", "exclusion": "1. Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.\n2. When prompted by your primary controller, click the button three times in one second", "reset": "Press Z-Wave button 3 times quickly, and hold the third time for at least 10 seconds.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4193/MSE30Z%20Manual-202106024.pdf" } }