{ "manufacturer": "TechniSat", "manufacturerId": "0x0299", "label": "Single-Switch", "description": "Flush On/Off Switch", "devices": [ { "productType": "0x0002", "productId": "0x1a90" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Central Scene: Multiple Button Presses", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Enabled", "value": 1 } ] }, { "#": "2", "label": "Report Interval", "description": "Interval of unsolicited meter reports in 10s increments; 0 to disable.", "valueSize": 2, "unit": "10s", "minValue": 0, "maxValue": 8640, "defaultValue": 3 }, { "#": "3", "label": "Energy Meter Report Interval", "description": "Interval of active energy meter reports in minutes; 0 to disable.", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 30240, "defaultValue": 60 }, { "#": "4", "label": "Button Mode", "description": "Switching mode of the push buttons", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Top: Turn off, bottom: Turn on", "value": 0 }, { "label": "Toggle the output", "value": 1 } ] }, { "#": "5", "label": "Input S: Button Mode", "description": "Switching mode of the push buttons", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Toggle switch", "value": 0 }, { "label": "Momentary switch", "value": 1 } ] }, { "#": "6", "label": "Input S: Central Scene Events for Multiple Button Presses", "description": "Which Central Scene to trigger on multiple button presses (2x-5x) of extension input S", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Central Scene 1", "value": 1 }, { "label": "Central Scene 2", "value": 2 }, { "label": "Central Scene 3 (Exclusive to input s)", "value": 3 } ] } ] }