{ "manufacturer": "Zooz", "manufacturerId": "0x027a", "label": "ZSE09", "description": "Motion and Light Mini Sensor", "devices": [ { "productType": "0x0003", "productId": "0x0083" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Motion Sensitivity", "description": "8 = high; 255 = low", "valueSize": 1, "minValue": 8, "maxValue": 255, "defaultValue": 12, "unsigned": true }, { "#": "2", "label": "Re-Trigger Interval", "valueSize": 2, "unit": "seconds", "minValue": 5, "maxValue": 600, "defaultValue": 30 }, { "#": "3", "$import": "templates/zooz_template.json#trigger_action" }, { "#": "4", "$import": "~/templates/master_template.json#base_enable_disable_255", "label": "Motion Detection", "defaultValue": 255 }, { "#": "5", "label": "Light Trigger Level", "description": "Max Light level which enables motion trigger", "valueSize": 2, "unit": "lux", "minValue": 0, "maxValue": 1000, "defaultValue": 100 }, { "#": "6", "label": "Motion Trigger Interval", "description": "Minimum time between motion triggers.", "valueSize": 1, "unit": "seconds", "minValue": 1, "maxValue": 8, "defaultValue": 8 }, { "#": "7", "label": "Light Polling Interval", "description": "Interval between light level reporting", "valueSize": 2, "unit": "seconds", "minValue": 60, "maxValue": 36000, "defaultValue": 180, "unsigned": true }, { "#": "8", "label": "Light Trigger", "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Enabled", "value": 255 } ] }, { "#": "9", "$import": "~/templates/master_template.json#base_0-255_nounit", "label": "Light Reporting Threshold", "unit": "lux", "defaultValue": 255, "unsigned": true }, { "#": "10", "$import": "~/templates/master_template.json#base_enable_disable", "label": "LED Notifications", "defaultValue": 1 } ] }