{ "manufacturer": "Zooz", "manufacturerId": "0x027a", "label": "ZEN55 LR", "description": "DC Signal Sensor", "devices": [ { "productType": "0x0004", "productId": "0x0110" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "$import": "~/templates/master_template.json#enable_led_indicator", "defaultValue": 1 }, { "#": "2", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Turn On Relay On Alarm", "defaultValue": 1 }, { "#": "3", "$import": "templates/zooz_template.json#auto_off_timer_5x" }, { "#": "4", "$import": "templates/zooz_template.json#auto_on_timer_5x" }, { "#": "5", "$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev" }, { "#": "6", "label": "Group 2 (Smoke Alarm): Basic Set Configuration", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Smoke detected: 0xff (On); No smoke: 0x00 (Off)", "value": 0 }, { "label": "Smoke detected: 0x00 (Off); No smoke: 0xff (On)", "value": 1 }, { "label": "Smoke detected: 0xff (On); No smoke: No command", "value": 2 }, { "label": "Smoke detected: 0x00 (Off); No smoke: No command", "value": 3 }, { "label": "Smoke detected: No command; No smoke: 0x00 (Off)", "value": 4 }, { "label": "Smoke detected: No command; No smoke: 0xff (On)", "value": 5 } ] }, { "#": "7", "label": "Group 3 (CO Alarm): Basic Set Configuration", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "CO detected: 0xff (On); No CO: 0x00 (Off)", "value": 0 }, { "label": "CO detected: 0x00 (Off); No CO: 0xff (On)", "value": 1 }, { "label": "CO detected: 0xff (On); No CO: No command", "value": 2 }, { "label": "CO detected: 0x00 (Off); No CO: No command", "value": 3 }, { "label": "CO detected: No command; No CO: 0x00 (Off)", "value": 4 }, { "label": "CO detected: No command;( No CO: 0xff (On)", "value": 5 } ] }, { "#": "8", "label": "Enabled Features", "description": "After changing this parameter, the device must be excluded and re-included", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Smoke & CO sensor", "value": 1 }, { "label": "CO sensor", "value": 2 }, { "label": "Smoke sensor", "value": 3 }, { "label": "Relay, smoke & CO sensor", "value": 4 }, { "label": "Relay & CO sensor", "value": 5 }, { "label": "Relay & smoke sensor", "value": 6 }, { "label": "Relay", "value": 7 } ] }, { "#": "9[0x01]", "$if": "firmwareVersion >= 1.10", "label": "Report Type: Signal Sensor", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Binary Switch Report", "value": 0 }, { "label": "Basic Report", "value": 1 } ] }, { "#": "9[0x02]", "$if": "firmwareVersion >= 1.10", "label": "Report Type: Z-Wave", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Binary Switch Report", "value": 0 }, { "label": "Basic Report", "value": 1 } ] } ], "metadata": { "$import": "templates/zooz_template.json#zen5x_metadata", "manual": "https://cdn.shopify.com/s/files/1/0218/7704/files/zooz-800-lr-dc-signal-sensor-zen55-manual.pdf" } }