{ "manufacturer": "Zooz", "manufacturerId": "0x027a", "label": "ZEN07", "description": "Mini Plug On / Off Module ZEN07", "devices": [ { "productType": "0x0003", "productId": "0x0087" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Send Metering Report", "defaultValue": 1 }, { "#": "2", "label": "Metering Report Frequency", "valueSize": 2, "unit": "seconds", "minValue": 1, "maxValue": 65535, "defaultValue": 300, "unsigned": true }, { "#": "3", "label": "Overload Protection Threshold", "valueSize": 1, "unit": "A", "minValue": 1, "maxValue": 16, "defaultValue": 13 }, { "#": "4", "label": "Overload Protection LED Notification Threshold", "valueSize": 1, "unit": "A", "minValue": 1, "maxValue": 13, "defaultValue": 12 }, { "#": "5", "$import": "~/templates/master_template.json#enable_led_indicator", "defaultValue": 1 }, { "#": "6", "$import": "~/templates/master_template.json#base_1-100_nounit", "label": "Power Report Percentage Threshold", "unit": "%", "defaultValue": 5 }, { "#": "7", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev" }, { "#": "8", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Auto Turn-Off Timer" }, { "#": "9", "label": "Auto Turn-Off Timer Interval", "valueSize": 2, "unit": "minutes", "minValue": 1, "maxValue": 65535, "defaultValue": 150, "unsigned": true }, { "#": "10", "$import": "templates/zooz_template.json#local_control" } ] }