{ // Auto-On/Off-Timers for ZEN0x, ZEN1x (except ZEN15), ZEN3x and ZEN7x "auto_timer_base_0x_1x_3x_7x_nounit": { "valueSize": 4, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, "auto_timer_base_0x_1x_3x_7x": { "$import": "#auto_timer_base_0x_1x_3x_7x_nounit", "unit": "minutes" }, "auto_off_timer_0x_1x_3x_7x": { "label": "Auto Turn-Off Timer", "$import": "#auto_timer_base_0x_1x_3x_7x" }, "auto_on_timer_0x_1x_3x_7x": { "label": "Auto Turn-On Timer", "$import": "#auto_timer_base_0x_1x_3x_7x" }, // Auto-On/Off-Timers for ZEN5x with fixed time unit "auto_timer_base_5x": { "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 4294967295, "defaultValue": 0, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, "auto_off_timer_5x": { "label": "Auto Turn-Off Timer", "$import": "#auto_timer_base_5x" }, "auto_on_timer_5x": { "label": "Auto Turn-On Timer", "$import": "#auto_timer_base_5x" }, // Auto-On/Off-Timers for ZEN5x with variable time unit and 2-byte value "auto_timer_variable_unit_base_5x_short": { "description": "Unit is minutes or seconds, depending on time unit parameter", "valueSize": 2, "unit": "min/sec", "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, "auto_off_timer_variable_unit_5x_short": { "label": "Auto Turn-Off Timer", "$import": "#auto_timer_variable_unit_base_5x_short" }, "auto_on_timer_variable_unit_5x_short": { "label": "Auto Turn-On Timer", "$import": "#auto_timer_variable_unit_base_5x_short" }, // Auto-On/Off-Timers for ZEN5x with variable time unit and 4-byte value "auto_timer_variable_unit_base_5x_long": { "description": "Unit is minutes or seconds, depending on time unit parameter", "valueSize": 4, "unit": "min/sec", "minValue": 0, "maxValue": 4294967295, "defaultValue": 0, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, "auto_off_timer_variable_unit_5x_long": { "label": "Auto Turn-Off Timer", "$import": "#auto_timer_variable_unit_base_5x_long" }, "auto_on_timer_variable_unit_5x_long": { "label": "Auto Turn-On Timer", "$import": "#auto_timer_variable_unit_base_5x_long" }, // Different variants of the auto-timer unit selectors "auto_timer_unit_select_min_sec": { "label": "Auto Timer Unit", "valueSize": 1, "minValue": 1, "maxValue": 2, "defaultValue": 1, "unsigned": true, "options": [ { "label": "Minutes", "value": 1 }, { "label": "Seconds", "value": 2 } ] }, "auto_timer_unit_select_sec_min": { "label": "Auto Timer Unit", "valueSize": 1, "minValue": 1, "maxValue": 2, "defaultValue": 1, "unsigned": true, "options": [ { "label": "Seconds", "value": 1 }, { "label": "Minutes", "value": 2 } ] }, // Auto-On/Off-Timers for other series with fixed time unit "auto_timer_duration_base": { "valueSize": 4, "unit": "minutes", "minValue": 1, "maxValue": 65535, "defaultValue": 60, "unsigned": true }, "auto_off_timer_duration": { "label": "Auto Turn-Off Timer Duration", "$import": "#auto_timer_duration_base" }, "auto_on_timer_duration": { "label": "Auto Turn-On Timer Duration", "$import": "#auto_timer_duration_base" }, "enable_scene_control": { "$import": "~/templates/master_template.json#base_enable_disable", "label": "Scene Control", "description": "Enable or disable scene control functionality for quick double tap triggers." }, "enable_scene_control_3way": { "$import": "~/templates/master_template.json#base_enable_disable", "label": "Scene Control: Remote 3-Way Switch" }, "led_indicator_color": { "label": "LED Indicator Color", "valueSize": 1, "minValue": 0, "maxValue": 3, "defaultValue": 1, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "White", "value": 0 }, { "label": "Blue", "value": 1 }, { "label": "Green", "value": 2 }, { "label": "Red", "value": 3 } ] }, "led_indicator_color_extended": { "label": "LED Indicator Color", "valueSize": 1, "minValue": 0, "maxValue": 6, "defaultValue": 1, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "White", "value": 0 }, { "label": "Blue", "value": 1 }, { "label": "Green", "value": 2 }, { "label": "Red", "value": 3 }, { "label": "Magenta", "value": 4 }, { "label": "Yellow", "value": 5 }, { "label": "Cyan", "value": 6 } ] }, "led_indicator_color_extended_alternate_palette": { "label": "LED Indicator Color", "valueSize": 1, "minValue": 0, "maxValue": 6, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "White", "value": 0 }, { "label": "Purple", "value": 1 }, { "label": "Orange", "value": 2 }, { "label": "Cyan", "value": 3 }, { "label": "Red", "value": 4 }, { "label": "Green", "value": 5 }, { "label": "Blue", "value": 6 } ] }, "led_indicator_brightness": { "label": "LED Indicator Brightness", "valueSize": 1, "minValue": 0, "maxValue": 2, "defaultValue": 1, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Bright (100%)", "value": 0 }, { "label": "Medium (60%)", "value": 1 }, { "label": "Low (30%)", "value": 2 } ] }, "led_confirm_config_change": { "$import": "~/templates/master_template.json#base_enable_disable_inverted", "label": "LED Indicator: Confirm Configuration Change", "description": "Disable this feature when using the LED indicators in automations.", "defaultValue": 0 }, "smart_switch_mode_reporting": { "label": "Smart Bulb Mode: Reporting Behavior", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Switch always reports status and changes LED state", "value": 0 }, { "label": "No status or LED state change when physical (and Z-Wave) control disabled", "value": 1 } ] }, "smart_switch_mode_dimming_reporting": { "label": "Smart Bulb Mode: Dimming Reporting Behavior", "description": "Reporting behavior for local control and Z-Wave disabled / enabled, respectively. Final level for Z-Wave control actions is always sent as a Multilevel Switch report, regardless of setting.", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Each brightness level / Final level", "value": 0 }, { "label": "Final brightness level only for local dimming, regardless of control setting", "value": 1 } ] }, "smart_switch_mode_dimming_reporting_3_options": { "label": "Smart Bulb Mode: Dimming Reporting Behavior", "description": "Reporting behavior for local control and Z-Wave disabled / enabled, respectively. Final level for Z-Wave control actions is always sent as a Multilevel Switch report, regardless of setting.", "valueSize": 1, "minValue": 0, "maxValue": 2, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Each brightness level / Final level (Basic Set)", "value": 0 }, { "label": "Final brightness level only for local dimming, regardless of control setting", "value": 1 }, { "label": "Each brightness level / Final level (Multilevel Switch)", "value": 2 } ] }, "association_reports_binary": { "label": "Association Reports", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 1, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Binary Switch CC report (Z-Wave); Basic CC Set (Manual)", "value": 0 }, { "label": "Binary Switch CC report (Z-Wave / Manual)", "value": 1 } ] }, "association_reports_multilevel": { "label": "Association Reports", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 1, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Multilevel Switch CC Report (Z-Wave); Basic CC Report (Manual)", "value": 0 }, { "label": "Multilevel Switch CC Report (Z-Wave / Manual)", "value": 1 } ] }, "dimmer_ramp_rate": { "$import": "~/templates/master_template.json#base_0-99_nounit", "label": "Ramp Rate Off/On (Manual Control)", "unit": "seconds", "options": [ { "label": "Instant on/off", "value": 0 } ] }, "dimmer_on_ramp_rate": { "$import": "~/templates/master_template.json#base_0-99_nounit", "label": "Ramp Rate On (Manual Control)", "unit": "seconds", "defaultValue": 0, "options": [ { "label": "Instant on", "value": 0 } ] }, "dimmer_off_ramp_rate": { "$import": "~/templates/master_template.json#base_0-99_nounit", "label": "Ramp Rate Off (Manual Control)", "unit": "seconds", "defaultValue": 0, "options": [ { "label": "Instant off", "value": 0 } ] }, "zwave_on_dimmer_ramp_rate": { "$import": "~/templates/master_template.json#base_0-99_nounit", "label": "Ramp Rate On (Z-Wave)", "unit": "seconds", "defaultValue": 0, "options": [ { "label": "Instant on", "value": 0 } ] }, "zwave_off_dimmer_ramp_rate": { "$import": "~/templates/master_template.json#base_0-99_nounit", "label": "Ramp Rate Off (Z-Wave)", "unit": "seconds", "defaultValue": 0, "options": [ { "label": "Instant off", "value": 0 } ] }, "zwave_on_dimmer_ramp_rate_match_manual": { "$import": "~/templates/master_template.json#base_0-100_nounit", "label": "Ramp Rate On (Z-Wave)", "unit": "seconds", "defaultValue": 0, "options": [ { "label": "Instant on", "value": 0 }, { "label": "Match ramp rate for manual control", "value": 100 } ] }, "zwave_on_dimmer_ramp_rate_match_manual_255": { "$import": "~/templates/master_template.json#base_0-255_nounit", "label": "Ramp Rate On (Z-Wave)", "unit": "seconds", "defaultValue": 255, "options": [ { "label": "Instant on", "value": 0 }, { "label": "Match ramp rate for manual control", "value": 255 } ] }, "zwave_off_dimmer_ramp_rate_match_manual": { "$import": "~/templates/master_template.json#base_0-100_nounit", "label": "Ramp Rate Off (Z-Wave)", "unit": "seconds", "defaultValue": 0, "options": [ { "label": "Instant off", "value": 0 }, { "label": "Match ramp rate for manual control", "value": 100 } ] }, "zwave_off_dimmer_ramp_rate_match_manual_255": { "$import": "~/templates/master_template.json#base_0-255_nounit", "label": "Ramp Rate Off (Z-Wave)", "unit": "seconds", "defaultValue": 255, "options": [ { "label": "Instant off", "value": 0 }, { "label": "Match ramp rate for manual control", "value": 255 } ] }, "min_brightness": { "$import": "~/templates/master_template.json#base_1-99_nounit", "label": "Minimum Brightness", "unit": "%" }, "max_brightness": { "$import": "~/templates/master_template.json#base_1-99_nounit", "label": "Maximum Brightness", "unit": "%", "defaultValue": 99 }, "double_tap_enable": { "label": "Double-Tap Behavior", "valueSize": 1, "minValue": 0, "maxValue": 2, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Enable Double-Tap", "value": 0 }, { "label": "Disable Double-Tap, Single-Tap to Last Brightness", "value": 1 }, { "label": "Disable Double-Tap, Single-Tap to Full Brightness", "value": 2 } ] }, "single_tap_up_behavior": { "label": "Single-Tap Upper Paddle Behavior", "valueSize": 1, "minValue": 0, "maxValue": 3, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Previous brightness", "value": 0 }, { "label": "Configured custom brightness (parameter 18)", "value": 1 }, { "label": "Configured maximum brightness", "value": 2 }, { "label": "Full brightness", "value": 3 } ] }, "zen2x_double_tap_up_behavior": { "label": "Double-Tap Upper Paddle Behavior", "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Full brightness", "value": 0 }, { "label": "Configured maximum brightness (parameter 11)", "value": 1 } ] }, "zen7x_double_tap_up_behavior": { "label": "Double-Tap Upper Paddle Behavior", "valueSize": 1, "minValue": 0, "maxValue": 3, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Full brightness", "value": 0 }, { "label": "Configured custom brightness (parameter 18)", "value": 1 }, { "label": "Configured maximum brightness", "value": 2 }, { "label": "Double tap disabled", "value": 3 } ] }, "custom_brightness": { "label": "Custom Brightness Level", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 0, "unsigned": true, "options": [ { "label": "Previous brightness", "value": 0 } ] }, "local_dimming_speed": { "label": "Local Dimming Speed", "description": "The time it takes to get from 0% to 100% brightness when pressing and holding the paddle.", "valueSize": 1, "unit": "seconds", "minValue": 1, "maxValue": 99, "defaultValue": 5, "unsigned": true }, "local_dimming_speed_group_3_and_4": { "label": "Local Dimming Speed (Dimmer and Group 3 and 4)", "description": "The time it takes to get from 0% to 100% brightness of dimmer and smart bulbs associated with Group 3 and 4 when pressing and holding the paddle.", "valueSize": 1, "unit": "seconds", "minValue": 1, "maxValue": 99, "defaultValue": 5, "unsigned": true }, "night_light_mode": { "label": "Night Light Mode", "description": "Set the brightness level the dimmer will turn on to when off and when lower paddle is held down for one second.", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 20, "options": [ { "label": "Disable", "value": 0 } ] }, "external_switch_type_0-3": { "label": "External Switch Type", "valueSize": 1, "unsigned": true, "minValue": 0, "maxValue": 3, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Toggle switch", "value": 0 }, { "label": "Momentary switch", "value": 1 }, { "label": "Toggle switch with fixed actions", "value": 2 }, { "label": "Split 3-Way", "value": 3 } ] }, "external_switch_type_0-4": { "$import": "#external_switch_type_0-3", "maxValue": 4, "options": [ { "label": "Toggle switch", "value": 0 }, { "label": "Momentary switch", "value": 1 }, { "label": "Toggle switch with fixed actions", "value": 2 }, { "label": "Split 3-Way", "value": 3 }, { "label": "Garage door mode (momentary)", "value": 4 } ] }, "impulse_duration": { "label": "Impulse Duration", "description": "Expected duration of the impulse in Split 3-Way mode", "valueSize": 1, "unit": "seconds", "minValue": 2, "maxValue": 200, "defaultValue": 10, "unsigned": true }, "relay_type_behavior": { "label": "Relay Type", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Normally open (off when relay is open)", "value": 0 }, { "label": "Normally closed", "value": 1 } ] }, "local_control": { "$import": "~/templates/master_template.json#base_enable_disable", "label": "Local Control", "description": "Enables control through the physical inputs on the device", "defaultValue": 1 }, "local_programming": { "$import": "~/templates/master_template.json#base_enable_disable_inverted", "label": "Local Programming", "description": "Controls programming (eg. including/excluding) device through physical inputs, allowing the according input sequence to be used for scene control instead. Factory reset remains available." }, "local_zwave_control": { "label": "Local/Z-Wave Control", "description": "Reports are always sent to the hub, regardless of this setting.", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Local control disabled, Z-Wave control enabled", "value": 0 }, { "label": "Local and Z-Wave control enabled", "value": 1 }, { "label": "Local and Z-Wave control disabled", "value": 2 } ] }, "3way_switch_type": { "label": "3-Way Switch Type", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Toggle switch", "value": 0 }, { "label": "Momentary switch", "value": 1 } ] }, "3way_switch_type_dimmer": { "label": "3-Way Switch Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Toggle switch", "value": 0 }, { "label": "Toggle switch (with dimming control)", "value": 1 }, { "label": "Momentary switch (with dimming control)", "value": 2 }, { "label": "Momentary switch (with dimming control, but reduce after double click)", "value": 3 } ] }, "basic_set_value": { "label": "Motion Detection: Basic Set Value", "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "0xff for Motion; 0x00 for Clear", "value": 0 }, { "label": "0x00 for Motion; 0xff for Clear", "value": 1 } ] }, "motion_sensitivity_1_8": { "label": "Motion Sensor Sensitivity", "description": "1 = Low sensitivity, 8 = High sensitivity", "valueSize": 1, "minValue": 0, "maxValue": 8, "unsigned": true, "options": [ { "label": "Disable", "value": 0 } ] }, "binary_sensor_report": { "$import": "~/templates/master_template.json#base_enable_disable", "label": "Motion Detection: Send Binary Sensor Reports", "description": "If disabled, notification reports will be sent instead", "defaultValue": 1 }, "trigger_action": { "label": "Trigger Action", "description": "0 = Off (Basic Set), 255 = On (Basic Set), 1...99 = dimming level (Multilevel Switch)", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, "battery_report_threshold": { "label": "Battery Report Threshold", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 50, "defaultValue": 10, "unsigned": true }, "low_battery_alarm_threshold": { "label": "Low Battery Alarm Threshold", "valueSize": 1, "unit": "%", "minValue": 10, "maxValue": 50, "defaultValue": 20, "unsigned": true }, "basic_set_value_disable_on_off": { "valueSize": 1, "defaultValue": 1, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Basic Set on (0xff)", "value": 1 }, { "label": "Basic Set off (0x00)", "value": 2 } ] }, "zen31_switch_type": { "valueSize": 1, "defaultValue": 2, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Analog sensor with no pullup", "value": 0 }, { "label": "Analog sensor with pull-up", "value": 1 }, { "label": "Momentary switch", "value": 2 }, { "label": "Toggle switch (on when switch is on)", "value": 3 }, { "label": "Toggle switch (toggles with switch toggle)", "value": 4 } ] }, "zen16_switch_type": { "valueSize": 1, "defaultValue": 2, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Momentary", "value": 0 }, { "label": "Toggle (follow switch)", "value": 1 }, { "label": "Toggle (change state on toggle)", "value": 2 } ] }, "zen16_switch_type_v2": { "valueSize": 1, "defaultValue": 2, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Momentary", "value": 0 }, { "label": "Toggle (follow switch)", "value": 1 }, { "label": "Toggle (change state on toggle)", "value": 2 }, { "label": "Garage door (momentary mode for Z-Wave control)", "value": 3 } ] }, // zen16 and zen17 relay devices now (Zen16 FW >=2.0, Zen17 FW >= 1.04) share common definition for switch type (and value inversion) and input trigger duration "multi_universal_relay_switch_type": { "valueSize": 1, "defaultValue": 2, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Momentary", "value": 0 }, { "label": "Toggle (Follow switch)", "value": 1 }, { "label": "Toggle (Change state on toggle)", "value": 2 }, { "label": "Garage door (Momentary mode for Z-Wave control)", "value": 3 }, { "label": "Leak alarm (Water sensor)", "value": 4 }, { "label": "Heat alarm", "value": 5 }, { "label": "Motion alert", "value": 6 }, { "label": "Open/Close alert (Door sensor)", "value": 7 }, { "label": "CO alarm", "value": 8 }, { "label": "CO2 alarm", "value": 9 }, { "label": "On/Off report (Dry contact switch/sensor)", "value": 10 }, { "label": "Garage door mode (Relay), door sensor (Input)", "value": 11 } ] }, "multi_universal_relay_reverse_reported_value": { "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Values not reversed", "value": 0 }, { "label": "Leak alarm (Water sensor)", "value": 4 }, { "label": "Heat alarm", "value": 5 }, { "label": "Motion alert", "value": 6 }, { "label": "Open/Close alert (Door sensor)", "value": 7 }, { "label": "CO alarm", "value": 8 }, { "label": "CO2 alarm", "value": 9 }, { "label": "On/Off report (Dry contact switch/sensor)", "value": 10 } ] }, "multi_universal_relay_input_trigger_duration": { "valueSize": 1, "unit": "0.1 seconds", "minValue": 1, "maxValue": 100, "defaultValue": 5 }, "zen16_manual_control": { "valueSize": 1, "defaultValue": 1, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 }, { "label": "Disable (with switch reports)", "value": 2 } ] }, "zwave_ramp_rate": { "label": "Z-Wave Ramp Rate", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Rate matches configured physical rate (Parameter 9)", "value": 0 }, { "label": "Rate set independently", "value": 1 } ] }, "zen5x_metadata": { "inclusion": "1. Initiate inclusion (pairing) in the app (or web interface).\n2. TAP UP 3 TIMES QUICKLY if using traditional Z-Wave inclusion. \nSCAN THE QR CODE / ENTER THE 5-DIGIT PIN if using the new SmartStart method. The SmartStart security PIN is located on the back of the relay, next to the Z-Wave Plus logo.\n3. The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails", "exclusion": "1. Bring your Z-Wave gateway (hub) close to the relay if possible\n2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com) \n3. Click the Z-Wave button on the relay 3 times quickly (the LED indicator will start blinking green)\n4. Your hub will confirm exclusion, the LED indicator on the relay will turn green for 2 seconds, and the device will disappear from your controller's device list", "reset": "If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To reset the relay, click the Z-Wave button twice and hold it for 15 seconds. The LED indicator will flash during the process and turn red for 3 seconds to confirm successful reset." } }