{ "manufacturer": "Logic Group", "manufacturerId": "0x0234", "label": "ZIF5031", "description": "DIN Rail Interface", "devices": [ { "productType": "0x0003", "productId": "0x0111" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true }, "2": { "label": "Input 1 (Multilevel Report)", "maxNodes": 5 }, "3": { "label": "Input 2 (Multilevel Report)", "maxNodes": 5 }, "4": { "label": "Input 3 (Multilevel Report)", "maxNodes": 5 }, "5": { "label": "Input 4 (Multilevel Report)", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "$import": "templates/logic_group_template.json#status_led" }, { "#": "2", "$import": "templates/logic_group_template.json#led_brightness" }, { "#": "3", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Input 1 - Thermistor" }, { "#": "4", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Input 2 - Thermistor" }, { "#": "5", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Input 3 - Thermistor" }, { "#": "6", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Input 4 - Thermistor" }, { "#": "7", "$import": "templates/logic_group_template.json#input_calibration", "label": "Input 1 - Calibration" }, { "#": "8", "$import": "templates/logic_group_template.json#input_calibration", "label": "Input 2 - Calibration" }, { "#": "9", "$import": "templates/logic_group_template.json#input_calibration", "label": "Input 3 - Calibration" }, { "#": "10", "$import": "templates/logic_group_template.json#input_calibration", "label": "Input 4 - Calibration" }, { "#": "11", "$import": "templates/logic_group_template.json#input_report_interval", "label": "Input 1 Report Interval" }, { "#": "12", "$import": "templates/logic_group_template.json#input_report_interval", "label": "Input 2 Report Interval" }, { "#": "13", "$import": "templates/logic_group_template.json#input_report_interval", "label": "Input 3 Report Interval" }, { "#": "14", "$import": "templates/logic_group_template.json#input_report_interval", "label": "Input 4 Report Interval" } ], "metadata": { "inclusion": "Push the button in the hole near the 'INCLUSION' text with a non-conductive object. The LED will now start blinking", "exclusion": "Push the button in the hole near the 'INCLUSION' text with a non-conductive object. The LED will now start blinking", "reset": "Push the button in the hole near the 'INCLUSION' text with a non-conductive object for 10 seconds. Please use this procedure only when the network primary controller is missing or otherwise inoperable" } }