{ "manufacturer": "Nexia Home Intelligence", "manufacturerId": "0x0178", "label": "ZSENS930", "description": "Remote Temperature and Humidity Sensor", "devices": [ { "productType": "0x5253", "productId": "0x5433", "zwaveAllianceId": 1939 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Battery Reporting Interval", "valueSize": 1, "unit": "hours", "minValue": 0, "maxValue": 127, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "8", "label": "Temperature Delta Report Threshold (Group 1)", "valueSize": 1, "unit": "0.1°", "minValue": 1, "maxValue": 200, "defaultValue": 10, "unsigned": true }, { "#": "9", "label": "Periodic Temperature Report Interval (Group 1)", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 120, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "10", "label": "Temperature Delta Report Threshold (Group 2)", "valueSize": 1, "unit": "0.1°", "minValue": 0, "maxValue": 50, "defaultValue": 10 }, { "#": "11", "label": "Periodic Temperature Report Interval (Group 2)", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 120, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "16", "label": "Humidity Threshold (Group 1)", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 50, "defaultValue": 5 }, { "#": "17", "label": "Humidity Report Interval (Group 1)", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 120, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "18", "label": "Humidity Threshold (Group 3)", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 30, "defaultValue": 5 }, { "#": "19", "label": "Humidity Report Interval (Group 3)", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 120, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "20", "label": "Basic Set Commands", "description": "Determines which combination of Basic Set commands will be sent", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Enable parameters 2, 5, 12, 15", "value": 1 }, { "label": "Enable parameters 2, 5, 13, 14", "value": 2 }, { "label": "Enable parameters 3, 4, 12, 15", "value": 3 }, { "label": "Enable parameters 3, 4, 13, 14", "value": 4 } ] }, { "#": "6", "label": "Basic Set Retry Attempts", "description": "Number of extra attempts sent every minute", "valueSize": 1, "minValue": 0, "maxValue": 5, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "2", "label": "Send Basic Set On: Above Temperature", "valueSize": 1, "minValue": 15, "maxValue": 121, "defaultValue": 121, "unsigned": false, "options": [ { "label": "Disable", "value": 121 } ] }, { "#": "3", "label": "Send Basic Set On: Below Temperature", "valueSize": 1, "minValue": 15, "maxValue": 121, "defaultValue": 121, "unsigned": false, "options": [ { "label": "Disable", "value": 121 } ] }, { "#": "4", "label": "Send Basic Set Off: Above Temperature", "valueSize": 1, "minValue": 15, "maxValue": 121, "defaultValue": 121, "unsigned": false, "options": [ { "label": "Disable", "value": 121 } ] }, { "#": "5", "label": "Send Basic Set Off: Below Temperature", "valueSize": 1, "minValue": 15, "maxValue": 121, "defaultValue": 121, "unsigned": false, "options": [ { "label": "Disable", "value": 121 } ] }, { "#": "12", "label": "Send Basic Set On: Above Humidity Level", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "13", "label": "Send Basic Set On: Below Humidity Level", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "14", "label": "Send Basic Set Off: Above Humidity Level", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "15", "label": "Send Basic Set Off: Below Humidity Level", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 0, "options": [ { "label": "Disabled", "value": 0 } ] }, { "#": "7", "$import": "~/templates/master_template.json#temperature_scale_celsius_fahrenheit", "defaultValue": 1 }, { "#": "21", "label": "Temperature Offset Correction", "description": "Correct deviations in the device's temperature reading.", "valueSize": 1, "unit": "°F", "minValue": -7, "maxValue": 7, "defaultValue": 0, "unsigned": false }, { "#": "22", "label": "Humidity Offset Correction", "description": "Correct deviations in the device's humidity reading.", "valueSize": 1, "unit": "%", "minValue": -7, "maxValue": 7, "defaultValue": 0, "unsigned": false }, { "#": "23", "label": "Humidity Filter Time Constant", "valueSize": 1, "unit": "minutes", "minValue": 1, "maxValue": 60, "defaultValue": 30 } ], "metadata": { "inclusion": "Set your primary controller into inclusion mode. Press and release the \"Install\" button on the sensor. The \"Status\" LED will blink rapidly for 3 seconds indicating successful inclusion into the network", "exclusion": "Set your primary controller into exclusion mode. Press and release the \"Install\" button on the sensor. The \"Status\" LED will blink rapidly for 3 seconds indicating successful exclusion from the network", "reset": "Press and hold the \"Install\" button for 10 seconds. Factory Reset should only be used if the primary controller is missing or inoperable.", "wakeup": "Press the \"Install\" button three times rapidly to send a \"BATTERY_REPORT\" and \"WAKE_UP_NOTIFICATION\" (if installed on a network). The sensor will stay awake for 30 seconds." } }