{ "manufacturer": "Telldus Technologies AB", "manufacturerId": "0x0176", "label": "TZWP-102", "description": "Socket and Energy Meter", "devices": [ { "productType": "0x0003", "productId": "0x0003" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Overcurrent Protection", "description": "If current exceeds 16A load will be switched off", "defaultValue": 1 }, { "#": "2", "$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off" }, { "#": "3", "label": "Send Status When Load Changes", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Send Basic Report", "value": 1 }, { "label": "Basic Report when load status not changed by Z-Wave", "value": 2 } ] }, { "#": "4", "label": "Configure LED Mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "The LED follows the load status", "value": 0 }, { "label": "When operating plug, the LED is lit for 5 seconds", "value": 1 } ] }, { "#": "16", "label": "Power Consumption Reports: Change Threshold", "valueSize": 2, "unit": "W", "minValue": 0, "maxValue": 2500, "defaultValue": 50, "options": [ { "label": "Disabled", "value": 0 } ] }, { "#": "17", "label": "Power Consumption Reports: Relative Change Threshold", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 10, "options": [ { "label": "Disabled", "value": 0 } ] }, { "#": "101", "label": "Power (W) Report Interval", "description": "Allowable range: 5-2678400", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 600, "options": [ { "label": "Disabled", "value": 0 } ] }, { "#": "102", "label": "Energy (kWh) Report Interval", "description": "Allowable range: 5-2678400", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 3600, "options": [ { "label": "Disabled", "value": 0 } ] }, { "#": "103", "label": "Voltage (V) Report Interval", "description": "Allowable range: 5-2678400", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 0, "options": [ { "label": "Disabled", "value": 0 } ] }, { "#": "104", "label": "Current (A) Report Interval", "description": "Allowable range: 5-2678400", "valueSize": 4, "unit": "seconds", "minValue": 0, "maxValue": 2678400, "defaultValue": 0, "options": [ { "label": "Disabled", "value": 0 } ] } ] }