{ "manufacturer": "Qubino", "manufacturerId": "0x0159", "label": "ZMNKID", "description": "Flush OnOff Thermostat 2", "devices": [ { "productType": "0x0005", "productId": "0x0054" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Input I1 Switch Type", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Push-Button (Momentary)", "value": 0 }, { "label": "On/Off toggle switch", "value": 1 } ] }, { "#": "4", "label": "Input 1 Contact Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NO (Normally open) input type", "value": 0 }, { "label": "NC (Normally close) input type", "value": 1 } ] }, { "#": "40", "label": "Power Consumption Reporting Threshold", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 10 }, { "#": "42", "label": "Power Consumption Reporting(Time)", "valueSize": 2, "minValue": 0, "maxValue": 32767, "defaultValue": 600 }, { "#": "43", "label": "Hysteresis Upper Temperature Offset", "valueSize": 2, "minValue": 0, "maxValue": 450, "defaultValue": 5 }, { "#": "44", "label": "Hysteresis Lower Temperature Offset", "valueSize": 2, "minValue": 0, "maxValue": 450, "defaultValue": 5 }, { "#": "45", "label": "Antifreeze", "valueSize": 2, "minValue": -125, "maxValue": 1000, "defaultValue": 50 }, { "#": "59", "label": "Thermostat Mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Heat mode", "value": 0 }, { "label": "Cool mode", "value": 1 } ] }, { "#": "60", "label": "Too Low Temperature Limit", "valueSize": 2, "minValue": -150, "maxValue": 2120, "defaultValue": 50 }, { "#": "61", "label": "Too High Temperature Limit", "valueSize": 2, "minValue": 1, "maxValue": 2120, "defaultValue": 700 }, { "#": "63", "label": "Output Switch Selection", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NC", "value": 0 }, { "label": "NO", "value": 1 } ] }, { "#": "78", "label": "Scale Selection", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Degrees celsius", "value": 0 }, { "label": "Degrees fahrenheit", "value": 1 } ] }, { "#": "110", "label": "Temperature Sensor Offset Settings", "valueSize": 2, "minValue": -270, "maxValue": 270, "defaultValue": 0 }, { "#": "120", "label": "Temperature Sensor Reporting Threshold", "valueSize": 2, "minValue": 0, "maxValue": 270, "defaultValue": 5 } ] }