{ "manufacturer": "Qubino", "manufacturerId": "0x0159", "label": "ZMNHSD", "description": "DIN Rail Dimmer", "devices": [ { "productType": "0x0001", "productId": "0x0052" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Controller Updates", "maxNodes": 1, "isLifeline": true }, "2": { "label": "I1 basic on/off", "maxNodes": 16 }, "3": { "label": "I1 start/stop level change", "maxNodes": 16 }, "4": { "label": "Multilevel set", "maxNodes": 16 }, "5": { "label": "Multilevel sensor report", "maxNodes": 16, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Input Switch Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Mono-Stable switch type (Push button)", "value": 0 }, { "label": "Bi-Stable switch type", "value": 1 } ] }, { "#": "5", "label": "Working Mode", "description": "Module presentation on the user interface.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Dimmer", "value": 0 }, { "label": "Switch", "value": 1 } ] }, { "#": "10", "label": "Activate / Deactivate Functions ALL ON / ALL OFF", "description": "DIN dimmer module responds to commands ALL ON / ALL OFF", "valueSize": 2, "defaultValue": 255, "allowManualEntry": false, "options": [ { "label": "All on is not active, all off is not active", "value": 0 }, { "label": "All on is not active, all off active", "value": 1 }, { "label": "All on active, all off is not active", "value": 2 }, { "label": "All on active, all off active", "value": 255 } ] }, { "#": "11", "label": "Automatic Turning Off Output After Set Time", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32536, "defaultValue": 0, "options": [ { "label": "Auto off disabled", "value": 0 } ] }, { "#": "12", "label": "Automatic Turning on Output After Set Time", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32536, "defaultValue": 0, "options": [ { "label": "Auto on disabled", "value": 0 } ] }, { "#": "21", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Double Click Function", "description": "If Double click function is enabled, double click to maximum dimming power" }, { "#": "30", "$import": "~/templates/master_template.json#state_after_power_failure_prev_off" }, { "#": "40", "label": "Power Reporting in Watts on Power Change", "description": "Reporting the power in Watts on power change larger then the setpoint", "valueSize": 1, "unit": "%", "minValue": 0, "maxValue": 100, "defaultValue": 5 }, { "#": "42", "label": "Power Reporting in Watts by Time Interval", "valueSize": 2, "unit": "seconds", "minValue": 0, "maxValue": 32767, "defaultValue": 300 }, { "#": "60", "label": "Minimum Dimming Value", "valueSize": 1, "unit": "%", "minValue": 1, "maxValue": 98, "defaultValue": 1 }, { "#": "61", "label": "Maximum Dimming Value", "valueSize": 1, "unit": "%", "minValue": 2, "maxValue": 99, "defaultValue": 99 }, { "#": "65", "label": "Dimming Time (Soft On/off)", "description": "Set value means time of moving the Dimmer between min. and max. dimming", "valueSize": 2, "minValue": 1, "maxValue": 255, "defaultValue": 100 }, { "#": "66", "label": "Dimming Time When Key Pressed", "description": "Time to moving the Dimmer between min. and max values (in seconds).", "valueSize": 2, "minValue": 1, "maxValue": 255, "defaultValue": 3 }, { "#": "67", "label": "Ignore Start Level", "description": "Ignore or respect start level when used together with association group 3", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Respect start level", "value": 0 }, { "label": "Ignore start level", "value": 1 } ] }, { "#": "68", "label": "Dimming Duration", "description": "This parameter is used with association group 3.", "valueSize": 1, "minValue": 0, "maxValue": 127, "defaultValue": 0 }, { "#": "110", "label": "Temperature Sensor Offset Settings", "description": "32536 = no offset; 1-100 = 0.1 °C added; 1001-1100 = 0.1 °C subtracted", "valueSize": 2, "unit": "°C", "minValue": 1, "maxValue": 32536, "defaultValue": 32536 }, { "#": "120", "label": "Digital Temperature Sensor Reporting", "description": "Reporting temperature when change is larger than defined by this parameter", "valueSize": 1, "unit": "°C", "minValue": 0, "maxValue": 127, "defaultValue": 5 } ] }