{ "manufacturer": "Qubino", "manufacturerId": "0x0159", "label": "ZMNHMD", "description": "Smart Leak Protector", "devices": [ { "productType": "0x0006", "productId": "0x0051" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Output 1 Valve Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NO (Normally open)", "value": 0 }, { "label": "NC (Normally closed)", "value": 1 } ] }, { "#": "2", "label": "Input 2 Contact Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NO (Normally open)", "value": 0 }, { "label": "NC (Normally closed)", "value": 1 } ] }, { "#": "3", "label": "Input 3 Contact Type", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "NO (Normally open)", "value": 0 }, { "label": "NC (Normally closed)", "value": 1 } ] }, { "#": "30", "$import": "~/templates/master_template.json#state_after_power_failure_prev_off" }, { "#": "48", "label": "Total Water Consumption", "valueSize": 4, "unit": "l", "minValue": -2147483648, "maxValue": 2147483647, "defaultValue": 0 }, { "#": "50", "label": "Number of Liters Per Pulse", "valueSize": 2, "minValue": 1, "maxValue": 1000, "defaultValue": 10 }, { "#": "51", "label": "Slow Leak: Threshold", "description": "How much water must be consumed in the timespan defined by parameter 52 to trigger slow leak alarm", "valueSize": 2, "unit": "l", "minValue": 1, "maxValue": 1000, "defaultValue": 1 }, { "#": "52", "label": "Slow Leak: Time Interval", "valueSize": 1, "unit": "hours", "minValue": 1, "maxValue": 24, "defaultValue": 24 }, { "#": "60", "label": "Slow Leak: Close Valve on Alarm", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Enable", "value": 0 }, { "label": "Disable", "value": 1 } ] }, { "#": "53", "label": "Medium Leak: Threshold", "description": "How much water must be consumed in the timespan defined by parameter 54 to trigger medium leak alarm", "valueSize": 2, "minValue": 1, "maxValue": 1000, "defaultValue": 150 }, { "#": "54", "label": "Medium Leak: Time Interval", "valueSize": 1, "unit": "hours", "minValue": 1, "maxValue": 24, "defaultValue": 6 }, { "#": "61", "label": "Medium Leak: Close Valve on Alarm", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Enable", "value": 0 }, { "label": "Disable", "value": 1 } ] }, { "#": "55", "label": "Fast Leak: Threshold", "description": "How much water must be consumed in the timespan defined by parameter 56 to trigger fast leak alarm", "valueSize": 2, "minValue": 1, "maxValue": 1000, "defaultValue": 300 }, { "#": "56", "label": "Fast Leak: Time Interval", "valueSize": 1, "unit": "hours", "minValue": 1, "maxValue": 24, "defaultValue": 3 }, { "#": "62", "label": "Fast Leak: Close Valve on Alarm", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Enable", "value": 0 }, { "label": "Disable", "value": 1 } ] }, { "#": "63", "label": "Hardware Leak: Close Valve on Alarm", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Enable", "value": 0 }, { "label": "Disable", "value": 1 } ] } ] }